Vd sets the data display screen – Yokogawa µR20000 User Manual

Page 59

Advertising
background image

4-16

IM 04P01B01-17E

Query

SJ[p1]?

Example Enable timer 1 on computation channel 0B. No

sum scale designation.
SJ0B,1,OFF

Description • This command cannot be specified while

computation is in progress.

• About p3
The data for sum computation are sampled

every scan interval. For data with units such
as /s, /min, /h, and /day as in a flow rate, the
data can be summed over the unit time as
shown below. Parameter p3 is valid only for
sum values.

OFF Σ (measured value)
/s

Σ (measured value) × scan interval

/min Σ (measured value) × scan interval/

60

/h

Σ (measured value) × scan interval/

3600

/day Σ (measured value) × scan interval/

(3600×24)

The unit of the scan interval is seconds.

VD

Sets the data display screen.

On screens without detailed parameters

Syntax

VD p1,p2<terminator>
p1 Screen number (01 to 15)
p2 Display type

4CH bargraph

4-channel bar graph display (pen
model)

6CH bargraph

6-channel bar graph display (µR10000
dot model)

Channel alarm status

Channel alarm status display

Time/Chart speed

Date/Time/Chart speed display

DI/DO

DI/DO status display

STATUS

Status display

System

System display

Batch name

Batch name (/BT1 option)

Lights out

Screen OFF

SKIP

Skip

Query

VD[p1]?

Example Assign the status display to screen 02.

VD02,STATUS

On screens with the displayed channel switching

interval

Syntax

VD p1,p2,p3<terminator>
p1 Screen number (01 to 15)
p2 Display type

1CH digital

1-channel digital display

2CH digital

2-channel digital display

4CH digital

4-channel digital display

6CH digital

6-channel digital display (dot model)

12CH digital

12-channel digital display (µR20000
12, 18 and 24 dot model)

1CH digital+1CH bargraph

1-channel digital display + 1 channel
bar graph display

1CH digital+4CH bargraph

1-channel digital display + 4 channel
bar graph display (pen model)

2CH digital+2CH bargraph

2-channel digital display + 2 channel
bar graph display

Tag_1CH digital

1-channel digital display (tag)

Tag_2CH digital

2-channel digital display (tag)

Tag_1CH digital+1CH bargraph

1-channel digital display + 1 channel
bar graph display (tag)

Tag_1CH digital+4CH bargraph

1-channel digital display + 4 channel
bar graph display (tag, pen model)

p3 Displayed channel switching interval

MANUAL Fixed display channels, data

update rate (pen model): 2 s,
data update rate (dot model):
scan interval

AUTO1S Switch the displayed channels

and data every second.

AUTO2S Switch the displayed channels

and data every 2 seconds.

AUTO3S Switch the displayed channels

and data every 3 seconds.

AUTO4S Switch the displayed channels

and data every 4 seconds.

AUTO5S Switch the displayed channels

and data every 5 seconds.

Query

VD[p1]?

4.4 Setting Commands