Commands

1

2

3

4

5

6

App

Index

IM 04P01B01-17E

4-17

Example Assign the 2-channel digital display to screen 04

and automatically switch the displayed channels
every 5 seconds.
VD04,2CH digital,AUTO5S

For flag display

Syntax

VD p1,p2,p3<terminator>
p1 Screen number (01 to 15)
p2 Display type

FLAG

Flag display (fixed)

p3 Display ON/OFF for each channel

Specify the ON/OFF state of each channel
with 1 or 0 (see the explanation).

Query

VD[p1]?

Example 1 On the 6-dot model, assign the flag display to

screen 03 and display the flags of channel 01
and 02.
VD 03,FLAG,110000

Example 2 On the 2-pen model with the computation

function (/M1 option), assign the flag display to
screen 03 and display the flags of measurement
channel 02 and computation channels 0A, 0B,
0E, and 0F.
VD03,FLAG,01-11001100

Description Use the format below to specify the display ON/

OFF state of each channel.
• List the values one after another for all

channels and separate the measurement
channels and computation channels with a
hyphen.

• Channels cannot be omitted.
• The characters after the hyphen are valid only

on models with the computation function (/M1
option).

For multiple display (display in which different

screens can be assigned to the top and bottom

sections

Syntax

VD

p1,p2,p3,p4,p5,p6,p7,p8,p9,p10,p11,
p12<terminator>
p1 Screen number (01 to 15)
p2 Display type

Multiple display

Display in which different screens can
be assigned to the top and bottom
sections

p3 Top section display type

1CH digital

1-channel digital display

2CH digital

2-channel digital display

3CH digital

3-channel digital display (µR20000)

TIME

Date/Time (µR10000)

Chart speed

Chart speed (µR10000)

TIME/Chart speed

Date/Time/Chart speed (µR20000)

Channel alarm status

Channel alarm status display

STATUS

Status display

Lights out

Screen OFF

Tag_1CH digital

1-channel digital display (tag)

Note

Parameters that become invalid due to p3, p4, p8, or p9 setting

are skipped, and the next parameter is brought forward.

p4 Displayed channel switching interval

Condition: Set this parameter when p3 is
1CH digital or 2CH digital.
MANUAL Fixed display channels, data

update rate (pen model): 2 s,
data update rate (dot model):
scan interval

AUTO1S Switch the displayed channels

and data every 1 second.

AUTO2S Switch the displayed channels

and data every 2 seconds.

AUTO3S Switch the displayed channels

and data every 3 seconds.

AUTO4S Switch the displayed channels

and data every 4 seconds.

AUTO5S Switch the displayed channels

and data every 5 seconds.

p5 Channel number

Condition: This parameter can be
specified when p3 is

1CH digital, 2CH

digital, or Tag_1CH digital and p4
is

MANUAL.

p6 2nd channel number

Condition: This parameter is specified when
p3 is

2CH digital and p4 is MANUAL.

p7 3rd channel number

Condition: This parameter is specified when
p3 is

3CH digital and p4 is MANUAL.

p8 Bottom section display type

Same as p3

p9 Displayed channel switching interval

Same as p4

p10 Channel number

Same as p5

p11 2nd channel number

Same as p6

p12 3rd channel number

Same as p7

4.4 Setting Commands