Front panel – GW Instek PSU-Series User Manual User Manual
Page 190

PSU Series User Manual
190
Front Panel
Model
PSU 6-200
12.5-120
20-76 40-38 60-25
Display, 4 digits
Voltage accuracy
0.1% + mV
12
25
40
80
120
Current accuracy
0.2% + mA
600
360
228
114
75
Indications
GREEN LED's: CV, CC, V, A, VSR, ISR, DLY,
RMT, LAN, M1, M2, M3, RUN, Output ON
RED LED's: ALM, ERR
Buttons
Lock/Local(Unlock), PROT(ALM_CLR),
Function(M1), Test(M2), Set(M3), Shift,
Output
Knobs
Voltage, Current
USB port
Type A USB connector
Programming and Measurement (RS-232/485, USB, LAN,
GPIB)
Model
PSU
6-200 12.5-120 20-76 40-38 60-25
Output voltage
programming
accuracy
0.05% + mV
3
6.25
10
20
30
Output current
programming
accuracy
0.2% +
mA
200
120
76
38
25
Output voltage
programming
resolution
mV
0.2
0.4
0.7
1.3
2
Output current
programming
resolution
mA
6
4
2.5
1.2
0.8
Output voltage
measurement
accuracy
0.1% +
mV
6
12.5
20
40
60
Output current
measurement
accuracy
0.2% +
mA
400
240
152
76
50
Output voltage
measurement
resolution
mV
0.2
0.4
0.7
1.3
2
Output current
measurement
resolution
mA
6
4
2.5
1.2
0.8