Run test script, Operation – GW Instek PSU-Series User Manual User Manual
Page 89

OPERATION
89
2. Turn on the power. MS ON (Mass Storage) will
be displayed on the screen after a few seconds
if the USB drive is recognized. Conversely, MS
OFF will be displayed if removed.
VOLTAGE
CURRENT
VSR
LAN
RMT
ERR
DLY
ALM
ISR
M 1
M 2
M 3
RUN
C V
C C
V
A
Note
If the USB drive is not recognized, check to see
that the function settings for F-20 = 1 (page 102). If
not, reinsert the USB flash drive.
3. Configure T-02 (Test Copy) to 1~10
(save memory slot)
T-02 range
1~10
4. OK will be displayed when completed.
5. The script will now be available in the memory
slot the script was saved to.
Note
Error messages: If you load a file that is not
present on the USB drive “Err 002” will be
displayed on the display.
VOLTAGE
CURRENT
VSR
LAN
RMT
ERR
DLY
ALM
ISR
M 1
M 2
M 3
RUN
C V
C C
V
A
Run Test Script
Overview
A test script can be run from one of ten memory
slots.
Steps
1. Before a test script can be run, it
must first be loaded into one of the
10 memory save slots.