GW Instek PSU-Series User Manual User Manual
Page 97

CONFIGURATION
97
Socket Server
Enable/Disable
F-57
0 = Disable, 1 = Enable
Web Server
Enable/Disable
F-59
0 = Disable, 1 = Enable
Web Password
Enable/Disable
F-60
0 = Disable, 1 = Enable
Web Enter Password
F-61
0000~9999
UART Settings
UART Mode
F-70
0 = Disable UART, 1 = RS232,
2 = RS485
UART Baud Rate
F-71
0 = 1200, 1 = 2400, 2 = 4800,
3 = 9600, 4 = 19200, 5 = 38400,
6 = 57600, 7 = 115200
UART Data Bits
F-72
0 = 7 bits, 1 = 8 bits
UART Parity
F-73
0 = None, 1 = Odd, 2 = Even
UART Stop Bit
F-74
0 = 1 bit, 1 = 2 bits
UART TCP
F-75
0 = SCPI, 1 = TDK (emulation mode)
UART Address (For TDK) F-76
00 ~ 31
System Settings
Factory Set Value
F-88
0 = None
1 = Return to factory default settings
Show Version
F-89
0, 1 = Version
2, 3, 4, 5 = Build date (YYYYMMDD)
6, 7 = Keyboard CPLD
8, 9 = Analog Board CPLD
A, B = Analog Board FPGA
C, D, E, F = Kernel Build
(YYYYMMDD)
G, H = Test Command Version
I, J, K, L = Test Command Build
(YYYYMMDD)
Power On Configuration Settings*
CV Control
F-90
0 = Control by Local
1 = Control by External Voltage
2 = Control by External Resistor -
Rising
3 = Control by External Resistor -
Falling
4 = Control by Isolated Board