Cooling Performance EC Fans Extra Quiet

Ambient (°C)

25

30

35

40

Model

Supply Temp

Output

Input

Output

Input

Output

Input

Output

Input

°C

kW

kW

kW

kW

kW

kW

kW

kW

DCC011SX-04AK00

5

116.1

26.7

110.2

29.4

104.0

32.5

97.4

35.8

6

119.8

26.9

113.7

29.6

107.3

32.6

100.6

35.9

7

123.5

27.0

117.3

29.7

110.8

32.7

103.8

36.1

8

127.3

27.1

120.9

29.8

114.2

32.8

107.1

36.2

9

131.2

27.3

124.7

30.0

117.8

33.0

110.5

36.3

10

135.1

27.5

128.4

30.1

121.4

33.1

113.9

36.4

DCC014SX-04AL00

5

145.2

36.5

137.8

39.9

129.8

43.6

121.2

47.6

6

149.7

36.7

142.1

40.1

133.9

43.8

125.1

47.8

7

154.3

36.9

146.5

40.3

138.1

44.0

129.0

48.0

8

159.0

37.1

151.0

40.5

142.4

44.2

133.0

48.2

9

163.8

37.3

155.6

40.7

146.7

44.4

137.1

48.5

10

168.6

37.5

160.2

40.9

151.0

44.6

141.2

48.7

DCC017SX-04AM00

5

168.4

43.5

159.5

47.5

149.9

51.8

139.7

56.5

6

173.6

43.8

164.4

47.8

154.5

52.1

144.0

56.9

7

178.8

44.1

169.3

48.1

159.2

52.4

148.4

57.2

8

184.1

44.4

174.4

48.4

163.9

52.8

152.8

57.5

9

189.5

44.7

179.5

48.7

168.8

53.1

157.4

57.9

10

194.9

45.0

184.7

49.1

173.7

53.4

161.9

58.2

DCC021SX-06BS00

5

217.7

54.9

206.6

60.0

194.6

65.5

181.6

71.6

6

224.5

55.2

213.1

60.2

200.7

65.8

187.4

71.9

7

231.4

55.5

219.7

60.5

206.9

66.1

193.2

72.2

8

238.4

55.7

226.3

60.8

213.3

66.4

199.2

72.5

9

245.5

56.0

233.1

61.1

219.7

66.7

205.3

72.8

10

252.7

56.3

240.0

61.4

226.2

67.0

211.4

73.2

DCC023SX-04BT00

5

235.6

72.2

221.3

78.7

206.1

85.7

189.9

93.6

6

242.4

72.8

227.7

79.3

212.0

86.4

195.4

94.2

7

249.3

73.5

234.1

80.0

218.0

87.1

200.9

94.9

8

256.2

74.2

240.6

80.7

224.1

87.8

206.6

95.7

9

263.2

74.9

247.2

81.4

230.2

88.6

212.3

96.4

10

270.3

75.6

253.9

82.1

236.5

89.3

218.1

97.1

DCC024SX-06BT00

5

251.9

66.2

238.1

72.3

223.4

78.9

207.8

86.1

6

259.5

66.7

245.4

72.7

230.3

79.4

214.2

86.6

7

267.3

67.1

252.8

73.2

237.2

79.8

220.7

87.1

8

275.2

67.6

260.2

73.7

244.3

80.3

227.3

87.6

9

283.2

68.0

267.8

74.2

251.4

80.9

234.0

88.2

10

291.3

68.5

275.5

74.7

258.7

81.4

240.8

88.7

1

Output kW refers to the chilled water duty.

2

Input kW refers to the unit input power (compressor + fans).

3

Duties applicable for chilled water

T between 4 and 8°C.

4

Interpolate for water temperatures between those quoted, do not extrapolate.

5

Water flow rate (l/s) = Output ÷ (Cp x

T)

6

For conditions outside of those quoted please refer to Airedale.