Figure 17 – Badger Meter B3000 User Manual

Page 18

Advertising
background image

Compact Digital Flow Monitor, Model B3000

Page 18

March 2014

2

1

Roll-Over

Indicator

Totalizer

Mode

Total

Roll-Overs

Figure 17: Grand total

Test Test
The Test setting places the monitor into a special diagnostic mode that shows the current input frequency and the

accumulated input counts

Figure 18

shows the layout for test mode values The diagnostic mode makes it possible for the

user to see precisely the frequency input the monitor is seeing and is very useful in troubleshooting and noise detection

2

1

Input

Frequency

Totalizer

Counts

Figure 18: Test mode screen

If the current setting requires a change, press

► to advance to the alternate choice Once the correct choice is displayed, press

ENTER to save the new selection and advance to the next parameter
Select Meters K Factor Unit KFacUnt

Basic Function

At the KFacUnt prompt, press ENTER The display now shows the current K factor unit If the current selection is correct, press

ENTER to advance to the next parameter For meters calibrated in gallons, use Pul/Gal; for meters calibrated in cubic meters,

use Pul/m3; and so on
Enters Meters K Factor KFactor

Basic Function

OTE:

N

The K factor supplied with your meter or calculated from calibration data will be needed to complete this step

At the KFactor prompt, press ENTER The most significant digit in the K factor will begin to flash Using

▲ increment the

display digit until it matches the meter’s first K factor digit If the current selection is correct, press

► to advance to the next

digit Repeat this process until all K factor digits have been entered Press ENTER to save the K factor

OTE:

N

The number of digits available before and after the decimal point is determined by the bore size of the flow sensor

being used The largest K factors will be associated with the smallest bore sizes The maximum allowable K factor

is 99999 9 The minimum must be at least 1 000 If an out of range number is entered the display flashes Limit and

refuses to allow the entry