Battery Replacement (B30A/B/X/Z only)

Battery powered monitors use a single 3 6V DC “D” size, lithium battery When replacement is necessary, use a clean fresh

battery to ensure continued trouble-free operation

Replacement Batteries

Manufacturer

Part Number

Blancett

B300028

Xeno

S11-0205-10-03

Tadiran

TL-5930/F

Table 6: Replacement batteries

NEMA 4X Enclosure

Unscrew the four captive screws on the front panel to gain access to the battery Press the tab on the battery connector to

release it from the circuit board Remove the old battery and replace it with new one and then re-fasten the front panel

OTE:

N

The battery is held in place with a wire-tie that will need to be cut and replaced (see

Figure 30

) The approval on the

product requires the wire tie

2

1

Unscrew

Captive Screws

Freq. In

4-20mA

Iso Total Pluse

TR_B

TR_A

RS485 Gnd

Setpoint 1

Setpoint 2

Gnd

+

+

+

Total Reset

OC Total Pluse

Signal Gnd

+ –

KB/Display

J1

TB1

JP1

JP2

JP3

P2

Input

Total P

ulse

Sig
nal

P1

Mag

Pulse

Iso

OC

Low

High

Figure 30: NEMA 4X battery replacement

The solar powered variation uses a single nickle-cadmium battery and is not field replaceable

Explosion Proof Enclosure

DANGER

REMOVE (DE-ENERGIZE) ANY EXTERNAL POWER FROM THE UNIT BEFORE REMOVING THE SCREW COVER FROM THE

ENCLOSURE. FAILURE TO DO SO CAN BE DANGEROUS. (SEE

FIGURE 30

AND

FIGURE 31

)

1 Remove the screw cover from the enclosure body
2 Remove the two thumb screws and carefully remove the circuit board assembly far enough to access the

battery connector

3 Press the tab on the battery connector plug to release it from the battery connector socket
4 Remove the four screws holding the battery mounting plate to the enclosure base and then remove the battery

mounting plate