Normally open pushbutton switch – Badger Meter B3000 User Manual

Page 28

Advertising
background image

Compact Digital Flow Monitor, Model B3000

Page 28

March 2014

Clear Grand Total CLR G-T
Basic Function
At the Clr G-T prompt, press ENTER The display will now say no on the screen To clear the grand total press either

▲ or the ►

to change from no to yes Press ENTER to select yes and advance to the next parameter
The totalizer can also be reset using a hardware reset as shown in the following diagrams

JP1

JP2

JP3

Input

Total P

ulse

Sig
nal

P1

Freq. In

4-20mA

Iso Total Pluse

TR_B

TR_A

RS485 Gnd

Setpoint 1

Setpoint 2

Gnd

+

+

+

Total Reset

OC Total Pluse

Signal Gnd

TB1

Mag

Pulse

Iso

OC

Low

High

Normally Open

Pushbutton

Switch

Freq. In

4-20mA

Iso Total Pluse

+

+

+

Total Reset

OC Total Pluse

Signal Gnd

JP3

Total Pulse

ISO

OC

JP1

Input

Mag

Pulse

TB2

Normally Open

Pushbutton

Switch

Figure 28: NEMA 4X hardware reset

Figure 29: Ex-proof hardware reset

Password Passwd
Basic Function
Password protection prevents unauthorized users from changing programming information Initially, the password is set to

all zeros If the current setting requires a change, press ENTER at the Passwd prompt The first digit of the password begins to

flash Use

▲ to increment the digit until it matches the first number of the required password Use ► to advance to the next

digit of the required password value then use

▲ to increment the display digit until it matches the next digit of the required

password Repeat this step for the all the digits of the password and then press ENTER to save the new password and advance

to the next parameter
Reset Password RstPswd
Basic Function
Reset password parameter prevents unauthorized users from manually resetting the flow monitor’s main totalizer Initially, the

password is set to all zeros To change the reset password, press ENTER at the RstPswd prompt The first digit of the password

begins to flash Use

▲ to increment the digit until it matches the first number of the required password Use ► to advance to

the next digit of the required password value then use

▲ to increment the display digit until it matches the next digit of the

required password Repeat this step for the all the digits of the password and then press ENTER to save the new password and

advance to the next parameter

OTE:

N

Entering a password in the Passwd screen and leaving the password blank in the RstPswd screen allows for total resets

(not requiring a password), but restricts programming modification

Advertising