Badger Meter B3000 User Manual

Page 19

Advertising
background image

Programming Manual

Page 19

March 2014

Select Rate Units Setup Rate SU
Extended Function
The Rate SU is only available on the standard and solar liquid monitors For the most basic unit setup choices the B3000

monitor has a simple and advanced setup option accessed through the rate setup parameter If Simple is selected the rate and

total choices are reduced to the five most common combinations avoiding the need to make unit and interval choices When

Advanced is selected the monitor allows access to all rate, total, and interval parameters
Select Flow Rate Units Flo Unit
Basic Function (Simple Setting)
The monitor allows the choice of many common rate units Consult the

MENU MAPS on page 32

or the

SPECIFICATIONS on

page 7

for all the unit choices At the Flo Unit prompt, press ENTER The monitor now shows the current rate and totalizer

units choice flashing on and off If the current selection is correct, press ENTER to advance to the next parameter To change

to an alternate unit, use

▲ or ► to scroll to the required rate unit and press ENTER to save the choice

Select Rate (Time) Interval RateInt
Basic Function (Advanced Setting)
The term rate implies that something is occurring over a period of time Most people are familiar with the speed of a car

reported in miles per hour (mph) The same concept holds true for a flow meters based on sensing velocity The time choices

are Sec (seconds), Min (minutes), Hour (hours), and Day (days) At the Rate Int prompt, press ENTER The monitor now shows

the current time interval choice flashing on and off If the current selection is correct, press ENTER to advance to the next

parameter To change to an alternate time interval, use the use

▲ or ► to scroll to the required time interval and press ENTER

to save the choice
Select Flow Rate Units RateUnt
Basic Function (Advanced Setting)
The monitor allows the choice of many common rate units Consult the

MENU MAPS on page 32

or the

SPECIFICATIONS on

page 7

for all the unit choices At the RateUnt prompt, press ENTER The monitor now shows the current rate unit choice

flashing on and off If the current selection is correct, press ENTER to advance to the next parameter To change to an alternate

unit, use

▲ or ► to scroll to the required rate unit and press ENTER to save the choice

Select Total Units of Measure TotlUnt

Basic Function (Advanced Setting)

If a flow total is required, the units for the total must first be selected The monitor allows the choice of many common

totalization units Consult the

MENU MAPS on page 32

or the

SPECIFICATIONS on page 7

for all the unit choices At the

TotlUnt prompt, press ENTER The monitor shows the current total units If the current selection is correct, press ENTER to

advance to the next parameter To change to an alternate unit, use

▲ or ► to scroll to the required totalization unit and press

ENTER to save the choice
Select Total Multiplier TotlMul

Basic Function (Advanced Setting)

The monitor has a very versatile display that has the ability to accumulate the flow total in multiples of ten For example, if the

most desirable totalization unit is 1000 gallons, the monitor can easily be set up for this requirement Once the unit is back in

run mode, every time the total display increments by one digit the actual total would be an additional 1000 gallons At 1000

gallons the total display would read 1, at 3000 gallons the total display would read 3, and so on This feature eliminates having

to look at a total, count the digits, and mentally insert commas for each 1000 multiple
At the TotlMul prompt, press ENTER The monitor now shows the current total multiplier If the selection is correct, press

ENTER to advance to the next parameter To change to an alternate multiplier, use

▲ or ► to scroll to the required multiplier

unit and press ENTER to save the choice The multiplier choices: 0.01 (ч 100), 0.1 (ч 10), 1, x10, x100, x1000 units