METER GASKETS AND GROUNDING

Gasket and grounding requirements must be considered when determining the meter location, orientation and application .

Meter/Pipeline Connection Gaskets

You must install gaskets (not provided) between the detector's isolating liner

and the pipeline flange to ensure a proper and secure hydraulic seal . Use gaskets

that are compatible with the fluid . Center each gasket on the flange to avoid flow

restrictions or turbulence in the line .
During installation, do not use graphite or any electrically conductive sealing

compound to hold the gaskets . This could compromise the accuracy of the

measuring signal .
If you are using a grounding ring in the detector/pipeline connection, place the

ring between two gaskets . (See

"Pipelines with Cathodic Protection" on page 13

.)

GASKETS RECOMMENDED

Figure 15: Meter/pipeline connection gaskets

Meter Grounding

Process pipeline material can be either electrically conductive (metal) or not electrically conductive (made of or lined with

PVC, fiberglass or concrete) .
It is essential that the mag meter amplifier’s input ground (zero voltage reference) be electrically connected to the liquid media and

to a good, solid earth ground reference.

Conductive Pipe Grounding

To achieve an adequate ground, the meter body MUST be electrically connected to the liquid media . The mag meter flanges

are provided with grounding bolts for this purpose .
If the pipe material is electrically conductive, simply install grounding straps between these grounding bolts and the

mating flanges .
To ensure a good electrical connection at the mating flanges, we recommend that you drill and tap the flanges and install a

grounding screw (not provided) .
These grounding straps must be copper wire, at least 12 AWG size . They must be connected on both sides (inlet and outlet) of

the detector and to a local, earth ground .

Pipelines with Cathodic Protection

As for pipelines with cathodic protection, install meter potential-free . No electric connection from the meter to the pipeline

system may exist and power supply is to be provided via isolating transformer .

USE GROUNDING ELECTRODES (GROUNDING RINGS ALSO NEED TO BE INSTALLED ISOLATED FROM THE

PIPELINE SYSTEM).
Observe national rules for potential-free installations .

6 mm² Cu

"X"

M4:1

"X"

Electrically isolated

Electrically isolated

Figure 16: Cathodic protection

Meter gaskets and grounding

Page 13

July 2014

MAG-UM-00379-EN-02