Led status indicators, Specifications – Badger Meter M-Series M1000 User Manual

Page 32

Advertising
background image

SPECIFICATIONS

Flow Range

0 .03…12 m/s

Accuracy

± 0 .3% for velocities greater than 1 .64 ft/sec, ± 0 .0065 ft/sec for velocities less than 1 .64 ft/sec

Conductivity

Min . 5 µS/cm (20 µS/cm for demineralized water)

Fluid Temperature

With Remote AmplifierE:

PTFE 302° F (150° C),

Hard rubber 178° F (80° C)

With Meter-Mounted AmplifierE:

PTFE 212° F (100° C),

Hard rubber 178° F (80° C)

Ambient Temperature

–4…140° F (–20…60° C)

Flow Direction

Uni-directional or bi-directional

Analog Output

0/4…20 mA / 0…10 mA, flow direction is displayed on a separate status output

Pulse Output

2 open collectors, passive 32V DC, 0…100 Hz 100 mA, 100…10,000 Hz 20 mA, optional active

Frequency Output

Max . 10 kHz (open collector)

Communication

RS232, RS422, RS485 Modbus RTU

Empty Pipe Detection

Field-tunable for optimum performance based on specific application

Min-Max Flow Alarm

Programmable outputs 1…100% of flow

Low Flow Cutoff

Programmable 0…10% of maximum flow

Galvanic Separation

Functional 50 volts

Pulse Width

Programmable 5…500 ms

Coil Power

Pulsed DC

Repeatability

0 .1%

Sampling Rate

Programmable from 1 to 63 seconds . Standard sampling period is 15 seconds

Display

Two lines x 15 characters (7 on top + 8 on bottom), LCD display

Programming

3 external buttons

Units of Measure

Gallons, ounces, MGD, liters, cubic meters, cubic feet, imperial gallon, barrel, hectoliter and

acre feet

Power Supply

92…275V AC (50 / 60 Hz), <10 VA optional 9…36V DC

Amplifier Housing

Powder-coated aluminium die cast

Detector Housing

Carbon steel

Linear Materials

Hard Rubber, PFA, PTFE

Electrodes Materials

Standard: Hastelloy C

Optional Grounding Rings

Stainless steel

Mounting

Detector-mount or remote wall mount

NSF Listed

Models with hard rubber liner 4" size and up; PTFE liner, all sizes, listing in process

Cable Insertion

2 x M 20

Process Connection

Flange: DIN, ANSI, JIS, AWWA

Nominal Pressure

Up to 232 psi (16 bar)

Protection Class

Standard: NEMA 4X (IP66); Optional: NEMA 6P (IP67)

www.badgermeter.com

M-SERIES is registered trademark of Badger Meter, Inc . Other trademarks appearing in this document are the property of their respective entities . Due to continuous research,

product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding

contractual obligation exists . © 2014 Badger Meter, Inc . All rights reserved .

The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400

México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882

Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuffen | Germany | +49-7025-9208-0

Europe, Middle East Branch Office | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Office #C209 | Dubai / UAE | +971-4-371 2503

Czech Republic | Badger Meter Czech Republic s.r.o. | Maříkova 2082/26 | 621 00 Brno, Czech Republic | +420-5-41420411

Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01

Asia Pacific | Badger Meter | 80 Marine Parade Rd | 21-04 Parkway Parade | Singapore 449269 | +65-63464836

China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412

Control. Manage. Optimize.

Advertising