PHYSICAL SPECIFICATIONS (COMMON DATA FOR ALL VERSIONS)

Mounting

attachment to

stroke actuators

Direct, FlowPak/FlowTop

with attachment kit EBZG –E

For casting yoke acc to IEC 534-6 (NAMUR) with attachment kit EBZG –H or –H1
For pillar yoke acc to IEC 534-6 (NAMUR)

with attachment kit EBZG –K or –K1

Stroke range

With standard feedback lever (EBZG-A )

8…70 mm

With extended feedback lever (EBZG-B )

60…120 mm

With extended feedback lever (EBZG-A1)

110…260 mm

Larger stroke ranges can be realized with special levers

Mounting

attachment to

rotary actuators

acc. to VDI/VDE

3845

With attachment kit

EBZG -R

For more attachment kits, see

“Model Codes Attachment Kits” on page 31

For mounting orientation, see

“Model Codes Attachment Kits” on page 31

Materials

Housing and covers

Aluminum (Alloy No 230) finished with DD-varnish

All moving parts of feedback system

1 4306 / 1 4571 / 1 4104

Attachment kits

V4A or Aluminum, finished with DD varnish

(Depending upon version)

(Alloy No 230)

Mounting bracket

Aluminum (Alloy No 230)

Pneumatic diaphragms

PVMQ (Silicone elastomer, suitable for use in the paint

industry)

Weight

Single acting

approx 1 7 kg (3 7 lb)

Double acting

approx 2 0 kg (4 4 lb)

Pneumatic

connection

NAMUR mounting

G 1/4 for pipe diameter 6…12 mm (0 24…0 47 in ) for air

supply and outputs y1, y2 to the actuator; 1/4-18NPT with

additional connection manifold

Direct mounting

Instead of the output y1, an air connection on the back

with O-ring will be used (closed at NAMUR mounting)

Electrical

connection

Line entry

1 or 2 cable glands 1/2-14 NPT

or M20 x1 5

(others with Adapter AD-…)

Cable diameter

6…12 mm (0 24…0 47 in )

Screw terminals

2 terminals for input,

4 terminals for additional inputs / outputs

Wire cross section

0 3…2 5 mm

2

(AWG 22-14)

Test sockets

for options and communicator connection

Ambient

conditions

Operating conditions

acc to IEC 654-1

The device can be operated at a class Dx location
Ambient temperature

Operation

1)

– 40…80° C (– 40…176° F)

Transport and storage – 40…80° C (– 40 …176° F)

If the device is exposed to sunlight and the temperature may rise above 80° C, we recommend a sun

shade
Storage conditions

acc to IEC 60721-3-1: 1K5; 1B1; 1C2; 1S3; 1M2

Indicators

LCD (visible)

2)

: –25…70° C (–13…176° F)

LEDs (if present) : – 40…80° C (– 40…176° F)

Relative humidity

up to 100 %

Protection class

3)

acc to IEC 529, IP66

acc to NEMA, Type 4X

1) Details see Certificates of Conformity With Option -T only –20 °C

2) Below –20 °C the LCD reacts only slowly; above +70°C the background becomes dark

3) Under service as directed

4) With PROFIBUS or FOUNDATION Fieldbus only, if shield of wiring is grounded on both sides

5) Pneumatic connection 1/4-18NPT made with a seperate manifold delivered together with the device