MODEL CODES SRD991

Intelligent Positioner SRD991

010811

VERSION

Single Acting

-B

Double Acting

-C

Input/Communication

Intelligent without communication (4…20 mA)

D

HART Communication (4…20 mA)

H

FoxCom Communication (Digital/IT2)

(1)

F

PROFIBUS-PA (acc to FISCO)

P

FOUNDATION Fieldbus H1 (incl PID-Function Block, acc to FISCO)

Q

Additional Inputs/Outputs

Prepared For Additional In-/Outputs

N

Two Binary Outputs

P

Position Feedback 4 - 20 mA and one Binary Output for Alarm

(g)(e)

Q

Binary Inputs

(z)

B

Binary Inputs-Outputs (mandatory for ESD application

(z)

E

Position Feedback 4 - 20 mA and one Binary Output for Alarm

(z)

F

Built-In Limit Switch

Without Built-In Limit Switch

S

Inductive Limit Switch - Intrinsically Safe (Standard Version SJ2-N)

T

Inductive Limit Switch - Intrinsically Safe (Security Version SJ2-SN)

U

Inductive Limit Switch - Three wire version

(u)

R

Mechanical Switches (Micro-Switches) / UL- and CSA-approved

(u)

V

Potentiometer Input - CEM Filter (for Remote Mounting - main unit)

(k)

D

Cable Entry

M20 x 1 5 Without Cable Gland

1

1/2"-14 NPT (with Adapter(s) M20x1 5 to 1/2"-14 NPT)

6

M20 x 1 5 With One Plastic Cable Gland

7

Electrical Classification

Without Ex

ZZZ

for Input/Communication D, H

(y)

for Input/Communication H, F

(x)

EEx ia IIC T4 according to ATEX

(c)

EA4

II 2 G EEx ia IIC T6 according to ATEX)

(d

EAA

II 3 D/D Ex n T4 according to ATEX

(b)

2C4

II 3 D/D Ex n T6 according to ATEX

(b)

2CA

II 2 G EEx ia IIC T4 according to ATEX + Zone 20 Dust

(c)

ED4

II 2 G EEx ia IIC T6 according to ATEX + Zone 20 Dust

(d)

EDA

FM Nonincendive for Class I, Division 2, Groups A, B, C, D,

Hazardous Locations Indoors And Outdoors, NEMA 4X

for Input/Communication D, H

(y)

NFM

FM Approved for Intrinsic Safety Class I, Division 1, Groups A, B, C, D,

Hazardous Locations Indoors And Outdoors, NEMA 4X

for Input/Communication D, H

(y)

FAA

CSA Approved for Intrinsic Safety Class I, Division 1, Groups A, B, C, D,

Hazardous Locations Indoors And Outdoors, NEMA 4X

for Input/Communication D, H

(y)

CAA

GOST Approved for Intrinsic Safety ExiaIICT4

(c)

GA4

GOST Approved for Intrinsic Safety ExiaIICT6, T4

(d)

GAA

Attachment Kit

Order as Auxiliary

N

Manifold

Pneumatic connection 1/4 - 18 NPT made of an additional manifold

Y

Pneumatic connection G 1/4

R

(a) ONLY WITH (additional Inputs/Outputs E) AND (Optional Feature -B)

(b) Not released

(c) Only with Input/Communication D, H

(d) Only with Input/Communication F, H, P and Q

(e) NOT WITH (electrical certification ZZZ, EA4, EAA, GA4, GAA)

(f) Available WITH (Version: C) AND (Built-in Limit Switch: S, D) AND (Electrical Classification: ZZZ, EA4, EAA, GA4, GAA, NFM, FAA) OR WITH (Version: B) AND (Built-in Limit Switch: S,

D) AND (Electrical Classification: ZZZ, EA4, EAA, GA4, GAA, NFM, FAA)

(g) Available ONLY WITH (Electrical Classification: FAA, NFM, CAA)

(h) Available WITH (Version: B) OR WITH (Version: C) AND (Optional Features: S)

(j) ONLY WITH (Built-in limit switch -S) AND (Electrical Classification -ZZZ)

(k) Only with ELECTRICAL CLASSIFICATION EA4, EAA or ZZZ

(l) NOT WITH (optional feature -N OR Z OR Z1)

(n) Only with Version -C

(s) Only available with Optional Feature LCD (-V01 to -Vxx)

(v) Only available for Input/Communication F, H, P and Q in connection with Electrical Classification ZZZ, FAA, NFM, EAA, CAA & GAA

(w) Only available for Version single-acting -B in connection with Input/Communication -D and -H (x) Only in connection with Optional Features -B

(y) Not with Optional Features -B

(z) Not available with Electrical Classification FAA, NFM and CAA