Two Binary In/Outputs – Code E
This option board is recommended for PST applications
Output
• 2 galvanically separated signals
• Limit signals / alarms freely configurable via local keys or

via communication

• Two-wire system, according to DIN 19234, for external

supply

Supply voltage

8…36V DC

1) 2)

Configured as

NAMUR signal

Limit value

not exceeded

< 1 mA

Limit value

exceeded

typ 6 mA

Device fault

< 50 μA

Configured as On/

Off signal

Limit value

not exceeded

< 50 μA

Limit value

exceeded

> 20 mA/20 V / > 40

mA/10 V

(power derated)

Reference

AB1 for upper, AB2 for lower limit

Terminals for AB1

3)

A: 81+ B: 82–

Terminals for AB2

3)

C: 83+ D: 84–

Input

The kind of Signals Input can be configured as On/Off or as

NAMUR signal in accordance (DIN 19234)

Configured as NAMUR signal:
Unloaded supply voltage

> 8 V

Input

Logic 0

> 0 35 mA, < 1 mA

Logic 1

> 2 2 mA, < 6 mA

Input current

limited to

approx 6 mA

Configured as On/Off signal:
Input

Logic 0

< 4 mA

Logic 1

> 6 mA

Signal voltage

range

8…36 V

1)

1) Other values in hazardous areas

2) On request we can specify higher voltage limits

3) Terminals 81…84 are marked as K21…K32 within certificate of conformity

Electrical Classification ATEX

See PTB 00 ATEX 2128 Certificate

One module “Additional inputs / outputs” 8 can be plugged

onto main electronics 40:

• 2 binary inputs or
• 2 binary outputs or
• 2 binary in/outputs or
• Position feedback and alarm