Inductive Limit Switch – Code T, U

Output

2 inductive proximity sensors acc to
DIN 19 234 or NAMUR for connection to
switching amplifier

1)

Current
Consumption

Vane clear

> 2 2 mA

Vane interposed

< 1 mA

For control circuit
with the following
electrical values:

Supply voltage

8V DC, R

i

approx 1

kOhm

Supply voltage
range

5…25V DC (with
"no Ex")

Residual ripple

< 10 % p p
permissible

Line resistance

< 100 Ohms

Response
Characteristic

2) 3)

Switching
differential

< 1

% switching point
repeatability

< 0 2 %

Terminals for GW1 41+, 42–
Terminals for GW2

51+, 52–

Electrical Classification ATEX of versions T and U
• For types of protection and temperature classes as basic

device, see

page 13

• Additions for this option, Type AI 638 K, in EC- Certificate

of Conformity PTB00ATEX2128:
◊ Types of protection and temperature classes as basic

device For use in hazardous areas in circuits certified

as Intrinsically Safe with the following maximum

values: Ui= 16 V, Ii= 25 mA, Pi= 64 mW

◊ Internal capacitance and inductance: Ci= 30 nF, Li=

100 μH The electric circuits of Built-in Limit Switch

are galvanically separated from all other circuits and

from earth

1) Operating mode min (= low) / max (= high) selectable by adjustment of

switch vanes

2) Data measured according to VDI/VDE 2177

3) With stroke 30 mm and lever length 90 mm switches)

5) Operating mode min (=low) / max (=high) selectable by adjusting the

respective vane

6) Operating mode normally open / normally closed selectable by vane adjustment

7) Approval according to UL (UL 1054) and CSA (CSA 22 2 No 55) at 6000 operations

and T = 65° C / 149° F

8) Based on EN 61058-1, at 10,000 operations and T = 85° C / 185° F
9) General rating at 50,000 operations and T = 85° C / 185° F

Inductive Limit Switch, Three-wire system – Code R

Input

Stroke / angle from actuator via positioner

feedback lever

Output

2 inductive proximity sensors,

three-wire system, LED indication, contact,

pnp

2)

Supply Voltage US

10…30V DC

Residual Ripple

± 10 %, Us = 30V

Switching

Frequency

2 kHz

Constant Current

100 mA

Response

Characteristic

6)

Gain

continuously

adjustable from 1:1

to approx 7:1

Switching

differential

< 1 % Switching

point

Repeatability

< 0 2 %

Terminals for GW1

42

Terminals for GW2

52

Supply

41+, 43–

1) Operating mode min (= low) / max (= high) selectable by adjustment of switch

vanes

2) Data measured according to VDI/VDE 2177

3) With stroke 30 mm and lever length 90 mm switches)

Mechanical Switches (Micro Switches) – Code V (Only

Without Ex Protection)

Input

Stroke / angle derived from positioner

feedback lever

Output

2 mechanical switches (micro

5) 6))

Manufacturer

Saia-Burgess

Type

V4NS-C4-AC1-UL (UL- and CSA-approved)

Parts set for

subsequent

mounting

Code V

EW 426 164 066

Absolute limit

values AC of

mechanical

switches built into

positioner

Umax

130V AC

7)

Imax

0 5 A (resistive Load)

7)

Imax

0 03 A (inductive Load)

8)

Absolute limit

values DC of

mechanical

switches built into

positioner

9)

Umax

1 A

Imax

1 A

Switching Differential

< 2 5 %

Terminals for SW1

41, 42

Terminals for SW2

51, 52

The circuit of the mechanical switches have to be protected

by a suitable fuse The diameter of the protective conductor

needs to be at least 1 5 mm² / AWG 16