Enter hose, Fluid product name, Quantity – Badger Meter Fluid Management System User Manual

Page 27: Enter for dispense

Advertising
background image

Meter Selection

Enter a preset meter (hose) ID for the product .

Enter Hose

- - -

5 . Enter a preset meter (hose) ID for the fluid product you want and

press ENTER .

• Only meters that are assigned to the current keypad can be selected .

• In the operation modes WO Validation HOST or WO Validation PC the system will check if the product you entered is assigned to this work

order .

Display Fluid

Fluid

Product Name

6 . The chosen fluid type is displayed for three seconds .

Product Quantity

Quantity

----

7 . Enter the desired quantity and press ENTER .

Optionally, the quantity assigned to this WO is shown .

• The quantity can be chosen between 0 .0…99 .9 and 100…999 units of measure .

• The preselection can be made with one decimal place .

• For quantities more than 100 units of measure, the meter counts down toward zero .

• A quantity of 0 .0 will deactivate the preselection on the RF meter . The RF meter will not latch and the user is required to hold the

trigger in the open position to dispense fluid . The user must press RESET on the RF meter to complete the dispense operation and
communicate the dispense order result to the keypad .

Dispense Confirmation

Enter for

Dispense

8 . Press ENTER to dispense the fluid .

The work order is now ready for being picked up by the RF meter (see

RF Mode, Standard Preselection Mode) .

User Manual