Rf mode (standard pre-selection mode) – Badger Meter Fluid Management System User Manual

Page 29

Advertising
background image

RF Mode (Standard Pre-Selection Mode)

Work Order Validation via the Dispense Keypad

0.00

L

7.2

Dispensed

Quantity

RF COM

Batch Size

When the battery pack is attached to the meter, the meter will

automatically enter the RF mode . The trigger is in a locked-out

position and no oil can be dispensed until a dispense order is

received by the meter .

1 . Press the RESET button on the meter to enable it to receive a dispense order provided by the Dispense Keypad . The trigger

will unlock .

2 . Pull the trigger to begin the dispensing of fluid . The valve will automatically lock in place, even though the trigger will fall

back to the closed position . The flow will automatically shut off when the programmed amount has been dispensed .

3 . To top off, pull the trigger to dispense fluid and release when the desired amount has been reached .

4 . Press the RESET button when finished . The total quantity will be transmitted to the keypad and the meter will return to a

locked-out position . The meter is now ready to receive the next dispense order from the keypad .

10 sec

02

Result stored in

Dispense Keypad

Preselection: Pull the trigger until it

latches and RELEASE the trigger.
No preselection (0 liter): Pull and HOLD

the trigger. The trigger won´t latch.

Press the

RESET button

Press the

RESET button

The red button will STOP

a dispense at any time.

Order stored in

Dispense Keypad

10 sec

02

CLACK

02

User Manual

Page 29

July 2014