Troubleshooting, Dispense keypad error messages, Meter error codes – Badger Meter Fluid Management System User Manual

Page 53: Dispense keypad error messages meter error codes

Advertising
background image

TROUBLESHOOTING

Dispense Keypad Error Messages

These error messages can be displayed by the Dispense Keypad . The associated action to reset the system is listed behind .

Message

Messages at the Dispense Keypad

Hose active hit hose reset

The selected meter currently has a dispense order in waiting to be processed, complete

the active order . Press RESET .

WO refused

The entered work order number is not valid and has been refused by host or FMS software .

Master is down

The master does not respond to a request from the Dispense Keypad

PC is down

The FMS software (KPS) is not responding to the Master Keypad . Only if WO validation PC is

activated .

HOST is down

The HOST (DMS) is not responding to the Master Keypad . Only if “WO Validation HOST” is

activated . Press RESET .

Host or PC is occupied

Master keypad is occupied by another job . Press RESET .

Wrong hose for fluid

The meter selected is not a valid meter for the fluid assigned for this WO .

↑ ↓

RF communication is in progress, please wait (10 sec) .

Meter Error Codes

The meter has several Error Codes that may display . These provide indication, at the meter, that there is an error in

communication between the meter and keypad .

Message

Messages at the Meter

F01

The meter radio is not working .
To clear the error, press the RESET button on the meter .

F02

The meter is not configured to a keypad .
To clear the error code, press the RESET button on the meter .
Verify that the meter radio address is configured properly .

F03

System busy .
To clear the error, press the RESET button on the meter .

F08

Meter lost connection to network .
Out of range—network connection lost .
Keypad not powered .
Meter moved out of range of keypad .

F09

Meter not connected to a network .
First time being powered up .
Network selected is not available .

SF0

(Scale Factor 0)

The Scale Factor setting for the meter is set to 0 .000 .
To input a valid Scale Factor for the meter follow the instructions in the Change Factory Settings section

of this manual .

All other

Error Codes

Are for factory purposes only .
To clear the meter, press RESET .

Press RESET once more at the meter .

User Manual

Page 53

July 2014