AUTO Mode (Autonomous)

MPORTANT

I

This function allows unauthorized dispenses. The dispense information will not be associated to any mechanic or operator.

• The total dispensed quantity will be stored under the general work order number (999999) .

• The AUTO sign at the display’s lower left corner indicates the manual mode .

Enter the AUTO Mode

To enter the AUTO Mode:

1 . Press and hold the TOTAL button .

2 . Press the following buttons one after the other: 10, 1, 0.1, AUTO .

You can use this same button sequence to return to RF mode.
The solenoid will now unlock and the meter may be used as a normal preselection meter .

3 . Press the AUTO button to enter the preselection .

Reset to Standard Mode

To return the meter to the standard preselection mode, press the RESET button and start a communication with the assigned

dispense (see

“Network Connect (CON) Menu” on page 24

and

“RF Mode (Standard Pre-Selection Mode)” on page 29

.

If the communication was successful (no “F02” error code) the meter will lockout and fall back in the preselection mode . The

total quantity, which has been dispensed during the AUTO mode, will be automatically transmitted to the Master Keypad . It

will be assigned to Misc. WO-Number (default 999999), with the user named as “???” . The dispense result will be marked with

the Status 16 for manual dispense .

Electrical Override

In case of an emergency or to interrupt a batch, the meter is equipped with an electrical override . This option automatically

closes the valve in the meter, stopping the flow immediately . The display will begin to flash because the meter does not sense

any flow . Batching can be continued after an override, even if the meter is in the middle of a programmed batch and the

display continues to flash .

1 . Press the red SHUTOFF button to activate the electrical override . This button can only be used when the valve is open .

2 . Press the RESET button to cue up the next batch and stop the display from flashing .