3 identification system – NORD Drivesystems BU0530 User Manual

Page 17

Advertising
background image

1 General

BU 0530 GB-3712

17

1.3 Identification system

Name for ordering SK 5xxE

Example:

SK 520 E- 751 - 340-A

- XXX

Configuration

500

5x dig. IN, 2x analog IN, 2x relay OUT, 1x analog OUT,
RS232/485

505* as for "500", however 24 V supply for the control unit

510* as for "500", but with additional "safe pulse block"

511* as "510", but additionally with 2x CANbus/CANopen

515* as for "510", however 24 V supply for the control unit

520

as "500", but additionally with 2x CANbus/CANopen, 2x dig. IN,
2x dig. OUT, incremental encoder input

525* as for "520", however 24 V supply for the control unit

530

as for "520", however with additional "safe pulse block" and
positioning control

535

as for "530", however 24 V supply for the control unit

540

as for 530, however additionally with PLC functionality and
multi-encoder interface

545 as for "540", however 24 V supply for the control unit

Power

Mains

112

323-A

340-A

350-A

250

250W

I

I

Size S

370

370W

1

1

550

550W

1

1

1

1

750

750W

1

1

1

1

111

1.1kW

2

2

2

151

1.5kW

2

2

2

221

2.2kW

2

2

2

301

3.0kW

3

3

3

401

4.0kW

3

3

3

551

5.5kW

5

4

4

751

7.5kW

5

4

4

112

11kW

6

5

5

152

15kW

7

5

5

182

18.5kW

7

6

6

222

22kW

6

6

302

30kW

7

7

372

37kW

7

7

452

45kW

8

8

552

55kW

8

8

752

75kW

9

9

902

90kW

9

9

Advertising