NORD Drivesystems BU0080 User Manual

Page 24

Advertising
background image

NORDAC DeviceNet Manual

24

BU

0080

GB

Parameter

Setting value / Description / Note

Comments

P741

... - 01

... - 13

Process data bus Out

SK 500E

... - 01 = Status word

Status word, source from
P509.

... - 02 = Actual value 1 (P543)
... - 03 = Actual value 2 (P544)
... - 04 = Actual value 3 (P545)

... - 05 = Bus I/O Out Bits (P481)

The displayed value
depicts all Bus In bit
sources linked with OR.

… - 06 = Parameter data Out 1
... - 07 = Parameter data Out 2
... - 08 = Parameter data Out 3
... - 09 = Parameter data Out 4
... - 10 = Parameter data Out 5

Data during parameter
transfer.

0000 ... FFFF (hex)

This

parameter

provides

information about the actual
status word and the actual
values that are transferred via
the bus systems.

... - 11 = Master function actual value 1
... - 12 = Master function actual value 2
... - 13 = Master function actual value 3

Actual value of master
function 502/P503.

P742 Database

version

0 ... 9999

Displays the internal database version of the FI.

P744 Configuration

SK 300E, SK 700E, SK 750E

This parameter displays the option modules detected by the FI.

The display with the ParameterBox is in plain text.

The possible combinations are displayed in code in the ControlBox. Both right digits indicate the
customer unit used and the two left digits indicate the special extension unit. The options vary
depending on the FI type.

Customer Unit SK CU1-…

Special extension unit SK XU1-...

0 ... 9999

No

IO

XX00

Basic

IO

XX01

Standard

IO

XX02

Multi

IO

XX03

USS

IO

XX04

CAN

IO

XX05

Profibus

IO

XX06

Encoder

01XX

PosiCon

02XX

P744 Configuration

SK 500E

This parameter displays the design status integrated in the FI. Display is in hexadecimal code
(SimpleBox, ControlBox, Bus system).

The display is in plain text when the ParameterBox is used.

0000 ... FFFF (hex)

SK 500E = 0000

SK 510E/511E/515E = 0000

SK 520E = 0101

SK 530E/535E = 0201

P745 Module

version

SK 300E, SK 500E

0.0 ... 3276.7

Design status (software version) of the technology unit (SK TU2/3-xxx), but only when a separate
processor is present, therefore not for SK TU2/3-CTR.

Have this data available if you have a technical query.