Internal status machine, Nordac devicenet manual – NORD Drivesystems BU0080 User Manual

Page 38

Advertising
background image

NORDAC DeviceNet Manual

38

BU

0080

GB

Sw itch-on

disabled

Standby

Activated

Operation enabled

Fast stop active

Error reaction

active

Fault

From all device statuses

3

4

5

6

8

4

5

5

Not on standby

Sw itching on the inverter

Loading relay applied

Fault

Error reaction complete

Bit0 = 0:

& Bit1 = 1:
& Bit2 = 1:
(xxxx x1xx xxxx x110)

Bit 3 = 0:

Bit0 = 1:

Bit3 = 1:

Bit2 = 0:

Bit1 = 0:

v Bit2 = 0:

Shut dow n

Enable voltage
Enable pulses

Disable operation

Sw itch on

Enable operation

Fast stop

Disable voltage
Fast stop

Priority of control com mands:
1. Disable voltage
2. Fast stop
3. Shut dow n
4. Enable operation
5. Sw itch on
6. Disable operation
7. Reset error

Designation of statuses:
1: Bit 0 = 0
2: Bit 6 = 1
3: Bit 0 = 1
4: Bit 1 = 1
5: Bit 2 = 1
6: Bit 5 = 0
7: Bit 2 & Bit 3 = 1
8: Bit 3 = 1

3

5

2

3

3

6

4

2

2

1

2

3

7

8

f = 0 reached
(fast stop complete)

Bit7 0

Î

1

Bit4 = 0:

Bit5 = 0:

Bit6 = 0:

Error acknow ledgement

Control bits
0. Ready for operation / shut dow n
1. Disable / enable voltage
2. Enable pulses / emergency stop
3. Disable / enable operation
4. Operation condition / block RUE
5. Enable / stop RUE
6. Enable / disable setpoint
7. Error acknow ledgement (0

Î

1)

10. Control data valid / invalid

11. Rotation right
12. Rotation left
14. Parameter set Bit 0
15. Parameter set Bit 1

4

5

6

Move dow n emergency stop ramp and

remain in 'Operation enabled'

Hold frequency

Setpoint = 0%

Bit0 = 0:

Shut dow n

5

2

Internal status machine

Bit3 = 1:

& Bit0 = 1

:

Enable operation

Sw itch on

2