4 class 05 – devicenet connection object, 5 class 40 (28hex) – motor data object, 5 class 40 (28 – NORD Drivesystems BU0080 User Manual

Page 40: Motor data object

Advertising
background image

NORDAC DeviceNet Manual

40

BU

0080

GB

6.5.4

Class 05 – DeviceNet Connection Object

The settings for each active connection can be read out in this object:

Instance 1: Expl.Message

Instance 2: Polling

Instance 3: Bit-Strobe

Instance 4: COS/Cyclic

Inst Attr.

Description

Type

Access

1 State

USINT

Get

2 Instance

Type

USINT

Get

3 transportClass_trigger

BYTE

Get

4 produced_connection_id

UINT

Get

5 consumed_connection_id

UINT

Get

6 initial_comm_characteristic

BYTE

Get

7 produced_connection_size

UINT

Get

8 consumed_connection_size

UINT

Get

9 expected_packet_rate

UINT

Get/Set

12 watchdog_timeout_action

USINT

Get

13 produced_con_path_length

UINT

Get

14 produced_connection_path EPATH

Get

15 consumed_con_path_length

UINT

Get

16 consumed_connection_path EPATH

Get

1-4

17 produced_inhibit_time

UINT

Get

6.5.5

Class 40 (28

hex

) – Motor Data Object

Motor-specific data can be set or read via the Motor Data Object. This object is only valid if the AC Profile is
switched on (see above)!

Inst Attr.

Description

Type

Access

3 Motor

type

USINT

Get

6 Stator current [0.1A]

UINT

Get

7 Rated voltage [V]

UINT

Get/Set

8 Rated motor power [W]

UDINT

Get/Set

9 Nominal

frequency

UINT

Get/Set

1

12 Number of poles

UINT

Get

Advertising