NORDAC AS-Interface Manual

36

BU

0090

GB

Parameter

Setting value / Description / Note

Comments

P546 (P)

Bus setpoint 1

In this parameter, a function is assigned to the delivered setpoint 1 (SW1) for bus control.

NOTE:

Further details can be found in the respective FI manual or in the description of P400.

0 ... 7 (47)

[ 1 ]

SK 300E, SK 700E SK 750E

0 =

Off

1 =

Setpoint frequency (16 bit)

2 =

16 Bit setpoint position (only posicon,
SK700/750E

)

3 =

32 Bit setpoint position (only posicon,
SK700/750E

and if PPO- type 2 or 4 are

selected)

4 =

Control terminals posicon (only posicon,
SK700/750E

, 16Bit)

5 =

Setpoint position (16 Bit) increment

1

(onlyposicon, SK700/750E)

6 =

Setpoint position (32 Bit) increment

1

(onlyposicon, SK700/750E)

7 =

Bus IO In Bits 0-7

SK 500E

0 =

Off

1 =

Setpoint frequency (16 bit)

2 =

Torque current limit (P112)

3 =

Actual frequency PID

4 =

Frequency addition

5 =

Frequency subtraction

6 =

Current limit (P536)

7 =

Maximum frequency (P105)

8 =

Actual PID frequency limited

9 =

Actual PID frequency monitored

10 =

Torque servo mode (P300)

11 =

Lead torque (P214)

12 =

Reserved

13 =

Multiplication

14 =

PI process controller actual value

15 =

PI process controller setpoint

16 =

PI process controller lead

17 =

Digital In bits 0...7

18 =

Reserved

19 =

Set relay (P434/441/450/455=38)

20 =

Set analog output (P418=31)

21 =

... 45 reserved

46 =

Setpoint torque process controller

47 =

Gearing transfer factor

P547 (P)

Bus setpoint 2

In this parameter, a function is assigned to the delivered setpoint 2 (SW2) for bus control.

0 ... 46 (47)

[ 0 ]

0 =

Off

1 =

Setpoint frequency

2 =

Torque current limit (P112)

3 =

Actual frequency PID

4 =

Frequency addition

5 =

Frequency subtraction

6 =

Current limit (not SK 300E)

7 =

Maximum frequency (not SK 300E)

8 =

Actual PID frequency limited

9 =

Actual PID frequency monitored

10 =

Torque (not SK 300E)

11 =

Torque lead (not SK 300E)

12 =

Control terminals posicon (not SK 300E)

13 =

Multiplication (not SK 300E)

14 =

PI process controller actual value

15 =

PI process controller setpoint

16 =

PI process controller lead

17 =

Digital In bits 0...7

18 =

Curve travel calculator (not SK 300E)

19 =

Set relay

20 =

Set analog output

21 =

... 45 Reserved

46 =

Setpoint, torque process controller
(not SK 300E)

47 =

Gearing transfer factor (only SK 500E)

P548 (P)

Bus setpoint 3

In this parameter, a function is assigned to the delivered setpoint 3 (SW3) for bus control. This is
only available if P546

3 (only applies for SK 700E / SK 750E).

0 ... 46 (47)

[ 0 ]

For setting values, see parameter (P547)