Sw itch-on

interlock

Ready for

sw itch-on

Sw itched on

Operation

enabled

Quick stop active

Error reaction

active

Error

From any device status

3

4

5

6

8

4

5

5

Not ready

for sw itch-on

Inverter sw itch-on

Loading relay activated

Error

Error reaction
completed

Bit0 = 0:

Stop

& Bit1 = 1:

voltage enabled

& Bit2 = 1:

impulse enabled

(xxxx x1xx xxxx x110)

Bit 3 = 0:

Block operation

Bit0 = 1:

sw itch on

Bit3 = 1:

operation enabled

Bit2 = 0:

Quick stop

Bit1 = 0:

Block voltage

v Bit2 = 0:

Quick stop

Priority of control com m ands:
1. Block voltage
2. Quick stop
3. Stop
4. Operation enable
5. Sw itch on
6. Operation disable
7. Reset error

Identification of statuses:
1: Bit 0 = 0
2: Bit 6 = 1
3: Bit 0 = 1
4: Bit 1 = 1
5: Bit 2 = 1
6: Bit 5 = 0
7: Bit 2 & Bit 3 = 1
8: Bit 3 = 1

3

5

2

3

3

6

4

2

2

1

2

3

7

8

f = 0 achieved
(Quick stop completed)

Bit7 0

Î

1

error acknow ledgement

Control Bits
0. Operational / Stop
1. Voltage enable / disable
2. Impulse enabled / Quick stop
3. Operation enable / disable
4. Operating condition / disable HLG
5. Enable / stop HLG
6. Setpoint enable / disable
7. Error acknow ledgement (0

Î

1)

10. Control data valid / invalid

11. Direction of rotation right
12. Direction of rotation left
14. Parameter set Bit 0
15. Parameter set Bit 1

4

5

6

Bit4 = 0:

Run dow n quick stop ramp and remain in

status ''Operation enabled''

Bit5 = 0:

Hold frequency

Bit6 = 0:

setpoint = 0%

Bit0 = 0:

Stop

5

Bit3 = 1:

operation enabled

& Bit0 = 1

: sw itch on

2

Internal status machine

2