NORD Drivesystems BU0090 User Manual

Page 37

Advertising
background image

4 Frequency inverters - settings and control elements

BU 0090 GB

37

4.1.3

Information parameters

Parameter

Setting value / Description / Note

Comments

P740

... - 01

... - 06

Process data bus In

SK 300E, SK 700E, SK 750E

0000 ... FFFF (hex)

Displays the actual control word and the setpoints.

... - 01

= Control word

... - 02

= Setpoint 1 (P546)

... - 03

= Setpoint 1 High byte

... - 04

= Setpoint 2 (P547)

... - 05

= Setpoint 3 (P548)

... - 06

= Bus I/O In Bits (P480)

P740

... - 01

... - 13

Process data bus In

SK 500E

... - 01 =

Control word...

Control word, source from P509.

... - 02 =

Setpoint 1

... - 03 =

Setpoint 2

... - 04 =

Setpoint 3

Setpoint data from main
setpoint P510 - 01.

... - 05 =

Bus I/O Out Bits (P480)

The displayed value depicts
all Bus In bit sources linked
with OR.

... - 06 =

Parameter data In 1

... - 07 =

Parameter data In 2

... - 08 =

Parameter data In 3

... - 09 =

Parameter data In 4

... - 10 =

Parameter data In 5

Data during parameter
transfer.

0000 ... FFFF (hex)

This parameter informs
about the actual control
word and the setpoints that
are transferred via the bus
systems.

... - 11 =

Setpoint 1

... - 12 =

Setpoint 2

... - 13 =

Setpoint 3

Setpoint data from auxiliary
setpoint
P510 -02.

P741

... - 01

... - 06

Process data bus Out

SK 300E, SK 700E, SK 750E

0000 ... FFFF (hex)

Displays the actual status word and actual values.

... - 01

= Status word

... - 02

= Actual value 1 (P543)

... - 03

= Actual value 1 High byte

... - 04

= Actual value 2 (P544)

... - 05

= Actual value 3 (P545)

... - 06

= Bus I/O In Bits (P481)

P741

... - 01

... - 13

Process data bus Out

SK 500E

... - 01 =

Status word

Status word, source from P509.

... - 02 =

Actual value 1 (P543)

... - 03 =

Actual value 2 (P544)

... - 04 =

Actual value 3 (P545)

... - 05 =

Bus I/O Out Bits (P481)

The displayed value depicts
all Bus In bit sources linked
with OR.

... - 06 =

Parameter data Out 1

... - 07 =

Parameter data Out 2

... - 08 =

Parameter data Out 3

... - 09 =

Parameter data Out 4

... - 10 =

Parameter data Out 5

Data during parameter
transfer.

0000 ... FFFF (hex)

This parameter provides
information about the actual
status word and the actual
values that are transferred
via the bus systems.

... - 11 =

Master function actual value 1

... - 12 =

Master function actual value 2

... - 13 =

Master function actual value 3

Actual value of master
function
P502/P503.