NORD Drivesystems BU0090 User Manual

Page 54

Advertising
background image

NORDAC AS-Interface Manual

54

BU

0090

GB

5.5.3

Parameter value (PWE)

For each parameter, the transfer of the parameter value (PWE) is always as a word (16 Bit) or double word
(32 Bit). Only one parameter value can be transferred in a telegram.
A 32 bit parameter value comprises PWE1 (high value word) and PWE2 (low value word, 4th word).
A 16 Bit parameter value is transferred in PWE2. For negative values the high word must be set to FFFF

hex

.

Note:

32- Bit parameter values are only used with the posicon option. All the relevant parameters are
described in the supplementary posicon manual.


The parameter value is transferred as an integer value. For parameters with resolutions 0.1 or 0.01 the
parameter value must be multiplied by the inverse of the resolution.

Example: A start-up time of 99.99 seconds is to be set:
99.99s

→ 99.99 * 1/0,01 = 99,99 * 100 = 9999. Therefore the value 9999

dec

= 270F

hex

must be transferred.

Advertising