KM9106 Operators Manual

10

4.3.2 Line Scroll Mode

Line scroll mode allows you to customise the display.

Use the

key to change the bottom line of the display. Once the correct line is

displayed press to confirm and move the line up. Select the next parameter and
repeat until all lines display the desired parameters.

Change bottom line using

NETT C . . . 0.0
O2 % . . . 20.9
CO ppm . . 0000
CO2 % . . . 0.0

to select and move
parameter up

O2 % . . . 20.9
CO ppm . . 0000
CO2 % . . . 0.0
CO2 % . . . 0.0

Select next parameter.
Repeat above until
display reads desired data

O2 % . . . 20.9
CO ppm . . 0000
CO2 % . . . 0.0
CO/CO2 R . . 0.0001