Changing an external array's port setting – HP XP Data Shredder Software User Manual

Page 116

Advertising
background image

2.

In the WWN tree, select the product name of the connected external array. The WWN of all ports

that are connected to the local array and are used appear in the WWN list.

3.

In the WWN list, select WWN you want to stop using. When you select the WWN identifying the

external array's port in the list, you can stop the use of all ports of the local array connected to

the port at one time.

4.

Right-click, and select Disconnect Paths. Selected items appear in blue italics in the WWN tree and

WWN list. The contents of the setting appears in the Preset list.
To check the setting details, right-click the setting in the Preset list, and select Detail. To cancel the

setting, right-click the setting in the Preset list, and select Delete.

5.

Click Apply. A confirmation message appears.

6.

Click OK.

Restoring paths to an external LU by specifying an external

array's WWN (Check Paths)

To restore the path between the local array and external array by specifying the WWN that identifies the

external array's port, select the WWN tree to display the WWN list.

NOTE:

The path must be in a status that can be restored.

1.

In the LU Operation pane, select the WWN tab. The WWN tree and WWN list appear.

2.

In the WWN tree, select the product name of the connected external array or the WWN identifying

the external array's port.
• If you select the product name of the connected external array, all WWNs that are connected

to the local array and are used appear in the WWN list.

• If you select the external array's WWN, connection information about the paths between the

selected WWN and local array ports appear in the WWN list.

3.

In the WWN list, select the WWN for which you want to restore the path.
• If you selected the product name of the connected external array in the WWN tree, select the

WWN identifying the external array's port in the WWN list. In this case, you can restore the

path of all ports of the local array connected to the WWN at one time.

• If you selected the external array's WWN in the WWN tree, select the path between the

selected WWN and the port of the local array. In this case, you can restore the selected

path to the port of the local array individually.

4.

Right click, and select Check Paths. Selected items appear in blue italics in the WWN tree and

WWN list. The contents of the setting appears in the Preset list.
To check the setting details, right-click the setting in the Preset list, and select Detail. To cancel the

setting, right-click the setting in the Preset list, and select Delete.

5.

Click Apply. A confirmation message appears.

6.

Click OK.

Changing an external array's port setting

You can change the setting of an external array's port by specifying the WWN that identifies the external

array's port in the WWN list. Use the Change Parameter pane (

Figure 60

) to change the port setting.