Errors in all paths to the external array, If each node uses a different external array – HP XP Data Shredder Software User Manual

Page 127

Advertising
background image

Errors in all paths to the external array

The following sections describe the recovery procedures for two examples when the error occurs in all

paths connected to the external array.

If each node uses a different external array

In the configuration in

Figure 64

, all of the NAS Blade system's user LUs are volumes in the external array.

Each node uses the volume of a different array. All of node 1's user LUs are volumes in external array 1.

Therefore, if an error occurs in the path between the local array and external array 1, the error occurs in

all paths connected from node 1 to external array 1. In this situation, no user LU is available for node 1.
The situation in

Figure 64

is as follows:

The NAS Blade system attempts to change resource group 1's execution node to node 2 because

no user LU can be used from node 1 (failover). However, node 2 cannot access volumes in

external array 1, the failover function failed, and an srmd executable error appears as error

information for resource group 1.

The file system's status is blocked on node 2 because of the failure of the failover of resource

group 1.

Clients cannot access volumes in external array 1, but can access volumes in external array 2.

The local array recognizes that the status of all file systems and volumes in external array 1

are blocked.

Figure 64 Error occurs on the path to the external array used for node 1
1.

Restore (for example, check the cable's connection status or change the switch) the status of the error

path between the local array and external array 1.

2.

Execute the Check Paths & Restore Vol. command using External Storage XP. For instructions, see

Checking the connection status and resuming external LU operations (Check Paths & Restore Vol.)

.

External Storage XP user guide

127