Determining, setting, or changing the external LU cache mode

You set the cache mode when you define external LUs. HP strongly recommends that you set cache

mode to Disabled for external LUs. For instructions on mapping external LUs in a new configuration,

see

Mapping external LUs (Add LU)

.

CAUTION:

Before you delete any LUs that you want to remap, carefully record necessary configuration information.

If you remap existing LUs with changed configuration settings (other than cache mode), you can lose

access to the LUs and the data they contain.

Determining if the cache mode is disabled

If you have an existing configuration and need to determine if your external LUs are configured with

cache mode disabled, follow this procedure:

1.

In the XP Remote Web Console main pane, click the External Storage button in the left pane. The LU

Operation pane appears.

2.

In the Device tree, select an external device group.

3.

In the Device list, check the Cache Mode setting (

Figure 19

). If cache mode is enabled, you should

change it to Disabled.

Figure 19 LU Operation pane, Cache Mode setting

Changing the cache mode

If you need to change the cache mode for existing external LUs, you must delete and remap the external

LU path and definition.