Path status and examples of recovery procedures (SVS200)

Table 24

shows examples of the recovery procedures when the path status is not normal. When the path

status is not normal, use

Troubleshooting External Storage XP

and this table to recover the path status. If

you cannot restore the path, contact your HP account support representative.

Table 24 Path status and examples of recovery procedures (SVS200)

Path Status

Examples of Recovery Procedure

LUN Manager might have changed the LU paths' settings.
Check the LU paths' settings. If the LU paths' settings changed, change

the settings back to the ones when the volume was mapped. Or use

External Storage XP to perform the Delete LU operation, and perform

the Add LU operation again.

External device setting changed

LUN Security XP Extension might have changed the volume's access

attribute.
Check the volume's access attribute. If the volume is protected by the

access attribute, release the protection.
The volume might have been set as a pair volume for data copy.
Check if the volume is set as a pair volume of Business Copy XP,

Continuous Access XP, Continuous Access XP Journal, or some other

copy program. If the volume is set as a pair volume, the volume might

be protected because of the pair status. If the volume is protected,

change the pair status or delete the pair.

Illegal request

LUN Security XP Extension might have changed the volume's access

attribute.
Check the volume's access attribute. If the volume is protected by the

access attribute, release the protection.
The volume might have been set as a pair volume for data copy.
Check if the volume is set as a pair volume of Business Copy XP,

Continuous Access XP, Continuous Access XP Journal, or some other

copy program. If the volume is set as a pair volume, the volume might

be protected because of the pair status. If the volume is protected,

change the pair status or delete the pair.

Response error

LUN Security XP Extension might have changed the volume's access

attribute.
Check the volume's access attribute. If the volume is protected by the

access attribute, release the protection.
There is a problem with connection to the external array. The following

are possible causes:

The fibre cable is not physically connected properly.

The topology setting does not match between the external and

target ports.

If the external array is connected through switches, the switches'

settings might not be appropriate.

Check if the fibre cable is connected properly, and then set the Fibre

Channel port properly using LUN Manager.

Cannot detect port

LUN Manager might have enabled LUN security.
Check if the LUN security is enabled or not. If LUN security is enabled,

disable LUN security.