Table 2 – HP XP Data Shredder Software User Manual

Page 18

Advertising
background image

Table 2 Storage arrays that can be connected as external arrays

Storage array

Notes

HP StorageWorks XP12000 Disk Array

•

In External Storage XP panes, the array appears

as “12000”.

•

Alternate paths are in Multi mode (meaning that

dynamic load balancing across multiple active

paths is enabled).

HP StorageWorks XP10000 Disk Array

•

In External Storage XP panes, the array appears

as “10000”.

•

Alternate paths are in Multi mode.

HP StorageWorks XP1024/XP128 Disk Array

•

In External Storage XP panes, the arrays appear

as “1024” and “128”, respectively.

•

Alternate paths are in Multi mode.

HP StorageWorks XP512/XP48 Disk Array

•

In External Storage XP panes, the arrays appear

as “512” and “48”, respectively.

•

Alternate paths are in Multi mode.

HP StorageWorks XP256 Disk Array

•

In External Storage XP panes, the array appears

as “256”.

•

Alternate paths are in Multi mode.

HP StorageWorks 200 Storage Virtualization System

•

In External Storage XP panes, the array appears

as “SVS200”.

•

Alternate paths are in Multi mode.

HP StorageWorks 3000/5000 Enterprise Virtual

Array (Active/Standby and Active/Active controllers)

or HP StorageWorks 4000/6000/8000 Enterprise

Virtual Array (Active/Active controllers)

•

In this user guide, the arrays appear as “EVA

array”.

•

In External Storage XP panes, the arrays appear

as “EVA”.

•

Alternate paths are in Single mode (meaning that

dynamic load balancing across multiple active

paths is not enabled).

HP StorageWorks MSA1000/1500 (Active/Standby)

•

In this user guide, the arrays appear as “MSA

array”.

•

In External Storage XP panes, the arrays appear

as “MSA”.

•

Alternate paths are in Single mode.

TagmaStore™ Universal Storage Platform subsystem

•

In this user guide, the array appears as

“TagmaStore™ USP subsystem”.

•

In External Storage XP panes, the array appears

as “USP”.

•

Alternate paths are in Multi mode.

TagmaStore™ Network Storage Controller subsystem

•

In this user guide, the array appears as

“TagmaStore™ NSC subsystem”.

•

In External Storage XP panes, the array appears

as “NSC”.

•

Alternate paths are in Multi mode.

TagmaStore™ Adaptable Modular Storage subsystem

•

In this user guide, the array appears as

“TagmaStore™ AMS subsystem”.

•

In External Storage XP panes, the array appears

as “AMS”.

•

Alternate paths are in Single mode.

18

Preparing for External Storage XP operations