A Notes on connecting external

arrays

NOTE:

If you have an EVA or MSA connected as external storage and you need to perform a firmware upgrade

on the EVA or MSA, you must use the EVA/MSA offline firmware upgrade function. When the EVA or

MSA is connected as XP external storage, online EVA/MSA firmware upgrade is not supported at this

time. Therefore, you must stop host I/O to the arrays in question, and issue the Disconnect Subsystem

command before the upgrade. After performing the upgrade, issue the Check Paths & Restore Vol.

command. See

Disconnecting external arrays or LUs

and

Checking the connection status and resuming

external LU operations (Check Paths & Restore Vol.)

for details. You must also perform these procedures

on other external arrays that do not support online firmware upgrade

NOTE:

If your application server contains boot devices from external arrays that are EVA or MSA-resident,

and you need to perform a firmware upgrade on the EVA or MSA, you must shut down any servers

that boot from these arrays (through the XP, or otherwise) before the upgrade procedure. Perform the

following steps:

1.

Power down the application server containing boot devices from the external array.

2.

From XP Remote Web Console, issue the Disconnect Subsystem command. See

Disconnecting external

arrays or LUs

for more information.

3.

Perform the external array firmware upgrade as directed in the external array's user documentation.

4.

From XP Remote Web Console, issue the Check Paths & Restore Vol. command after the firmware has

been upgraded. See the

Checking the connection status and resuming external LU operations (Check

Paths & Restore Vol.)

for more information.

5.

Power on the application server, and resume the applications.

If the boot device is from an external array that does not support online firmware upgrade, you also must

perform this procedures. See the firmware upgrade procedure for the external array for instructions.

Connecting Thunder 9500V subsystems

System parameters for connecting Thunder 9500V subsystems

Table 13

explains whether to specify system parameters when making settings for ports on the Thunder

9500V subsystem.

External Storage XP user guide