HP XP Data Shredder Software User Manual

Page 147

Advertising
background image

Table 16 Path status and examples of recovery procedures (Thunder 9500V

subsystems)

Path status

Examples of recovery procedures

LUN Manager may have changed the LU paths' settings.
Check the LU paths' settings. If the LU paths' settings changed, change

the settings back to the ones used when the volume was mapped.

Or use External Storage XP to perform the Delete LU operation, and

perform the Add LU operation again.

External device setting changed

Open LDEV Guard may have changed the volume's access attribute.
Check the volume's access attribute. If the volume is protected by the

access attribute, release the protection.
The volume may have been set as a pair volume for data copy.
Check if the volume is set as a pair volume for Business Copy XP,

Continuous Access XP, or another copy program. If the volume is set as

a pair volume, the volume might be protected because of the pair status.

If the volume is protected, change the pair status or delete the pair.

Illegal request

Open LDEV Guard may have changed the volume's access attribute.
Check the volume's access attribute. If the volume is protected by the

access attribute, release the protection.
The volume may have been set as a pair volume for data copy.
Check if the volume is set as a pair volume for Business Copy XP,

Continuous Access XP, or another copy program. If the volume is set as

a pair volume, the volume might be protected because of the pair status.

If the volume is protected, change the pair status or delete the pair.

Response error

Open LDEV Guard may have changed the volume's access attribute.
Check the volume's access attribute. If the volume is protected by the

access attribute, release the protection.
There is a problem with the connection to the external array. The

following are possible causes:

The fibre cable is not connected properly.

The topology setting between the external and target ports does

not match.

If the external array is connected through switches, the switches'

settings might not be appropriate.

Check if the fibre cable is connected properly, and use LUN Manager

to set the Fibre Channel port properly.

Cannot detect port

LUN Manager may have enabled host group security.
Check if host group security is enabled. If host group security is

enabled, disable host group security.

Connecting TagmaStore AMS and TagmaStore WMS

subsystems

System parameters for connecting TagmaStore AMS and TagmaStore WMS

subsystems

Table 17

explains whether to specify system parameters when making settings for ports on TagmaStore

AMS and TagmaStore WMS subsystems.

External Storage XP user guide

147

Advertising