If you plan to use the mapped external LU from the mainframe OS (volume is mapped with a

3380-x or 3390-x mainframe emulation type), you must select an external LU that consists of one

LDEV or you must first adjust the capacity of the external LU to be mapped. If multiple LDEVs exist

in one external LU and if numerous I/Os are made to these LDEVs, the read and write commands

might timeout. When the commands timeout, the SIM (21D2xx) is reported.

When mapping an external LU as internal LDEVs with emulation types other than OPEN-V, the

number of volumes and the volume capacity of the mapped internal LDEVs depends on the

original external LU's capacity and each emulation type's normal size. When mapping an

external LU using emulation types other than OPEN-V, an XP array management information area

is required in the mapped LU. This means that the capacity available after mapping is slightly

smaller than the actual external LU capacity. Available capacity decreases by the size of the

XP array management information area, and all prior data must be considered lost. For more

information, see the HP StorageWorks Flex Copy XP user guide.

Figure 12

shows an example where the external LU's original capacity is larger than (or a multiple

of) the normal size of the local array's emulation type (OPEN-3 in this example). Therefore, in this

example, the local array can realize two fully-sized OPEN-3 LDEVs, with some space (insufficient to

create a full OPEN-3) left over.

Figure 12 Ext. LU cap. is larger than the spec. emulation type's basic cap. (OPEN-3

ex.)
Figure 13

shows an example where the external LU's original capacity is smaller than the normal

size of the local array's emulation type. In this example, since the resulting space is insufficient to

create a local array OPEN-3 LDEV, you can designate it as either a local array OPEN-V or an

OPEN-3 CVS LDEV. If the external LU were an XP of OPEN-3 emulation type, forfeiting a small amount

of management space would also result in an OPEN-3 CVS volume or an OPEN-V.

Figure 13 External LU capacity is smaller than the specified emulation type's basic

capacity

IO Suppression mode can only be selected when the volume being mapped is set to the OPEN-V

emulation type. If a different emulation type is set, IO Suppression mode is automatically set

to Disable.

38

Preparing for External Storage XP operations