(Optional) To sort the Selected Pairs table, click Sort in the middle-left.

(Optional) To change the split type and the rate at which data is copied, which applies
to all new pairs, change the pair options.

For more information about changing pair options, see

“Changing BC Z pair options”

(page 47)

.

(Optional) To change MU numbers, do the following:

a. Select the line for the LDEV in the Selected Pairs table.

b. Click Edit Mirror Units.

c. In the Edit Mirror Units dialog box, specify the S-VOL’s L1mirror unit number, and click
OK.

(Optional) Change the pair options.

For more information about changing pair options, see

“Changing BC Z pair options”

(page 47)

.

(Optional) To remove an unwanted LDEV or pair from the Selected Pairs table, select the
line for the LDEV or pair you want to remove and click Remove.

For more information about removing rows to alter pair configuration, see

“???TITLE??????TITLE???Example 3: Workflow for simultaneously creating a pair with
two S-VOLs and another with one S-VOL”

.

6.

In the Confirm window of the Create Pairs wizard, complete the following and then click Apply:

For Task Name, type a name for the task.

Default: date-window name

Character and symbol limit: 32 alphanumeric except / : , ; * ? “ < > |

Case sensitive: Yes

For Go to tasks window for status, select to open the Tasks window.

The BC Z pair is created and the status is “PAIR”.

Related topics

“Pair splitting methods” (page 49)

.

“Changing BC Z pair options” (page 47)

.

“Viewing pair information for local replication” (page 64)

.