HP XP Racks User Manual

Page 53

Advertising
background image

NOTE:

If you are sharing BC Z P-VOLs with Cnt Ac-S Z or Cnt Ac-J Z S-VOLs, for more

information about the requirements and restrictions for using CG pair-split with shared volumes,
see

“Requirements, restrictions, and guidelines for using consistency group pair-split with

shared BC Z and Cnt Ac-S Z or Cnt Ac-J Z volumes” (page 21)

.

4.

Register the split time for the BC Z CG to indicate the time when you want to mirror the P-VOL
data in the S-VOL.

For more information about registering split times, see the Hitachi Business Continuity Manager
User Guide
.

The split type changes to Quick Split and the BC Z pairs are simultaneously split. The registered
split time remains enabled even after you split the BC Z pairs. You can register a new split
time or reset the split time.

NOTE:

Discontinuing use of the remote storage system or turning off the remote storage

system’s power cancels the pair-split operation.

For more information about registering a new split time for the BC Z CG, see

“Workflow for

registering new split times for BC Z consistency groups” (page 54)

.

For more information about resetting the split time, see

“Resetting split times” (page 54)

.

5.

If the pair-split operation fails, perform troubleshooting for CG pair-split failures (see

“Troubleshooting consistency group pair-split failures” (page 86)

).

6.

If you have specified a split time and you are splitting pairs with shared volumes, you must
complete the following:
a.

Delete the split time for the BC Z pair that has an S-VOL related to the R-JNL.

b.

Restore the pair. Complete one of the following:

- If you are using RWC, see

“Workflow for restoring BC Z pairs” (page 58)

.

- If you are using RAID Manager to run commands, run the following command on the
Cnt Ac-J Z pair:

pairresync -restore

For more information about this command, see the HP XP7 RAID Manager User Guide.

7.

Create the pairs.

“Resynchronizing or restoring BC Z pairs” (page 58)

.

Related topics

“Restrictions for consistency group pair-split” (page 54)

.

“Requirements, restrictions, and guidelines for using consistency group pair-split with shared
BC Z and Cnt Ac-S Z or Cnt Ac-J Z volumes” (page 21)

.

“Pair splitting methods” (page 49)

.

For more information about splitting BC Z pairs in a CG using IBM PPRC, see

“Splitting pairs

with CSUSPEND and PPRCOPY SUSPEND” (page 94)

.

Splitting BC Z pairs

53

Advertising
This manual is related to the following products: