HP XP Racks User Manual

Page 82

Advertising
background image

Description

SSB2 code

The emulation type of the P-VOL was 3390-A, and the pair task is rejected because of one of the
following reasons:

20C9

Mainframe Fibre CHA is not mounted.

Mainframe Fibre CHA is all blocked.

The S-VOL’s emulation type was 3390-A, and the pair task was rejected because of one of the following
reasons:

20CA

Mainframe Fibre CHA is not mounted

Mainframe Fibre CHA is all blocked

The P-VOL rejected the Add Pair RAID Manager command because the THP pool is initializing in
the THP or Smart V-VOL.

20D0

The S-VOL rejected the Add Pair RAID Manager command because the THP pool is initializing in
the THP or Smart V-VOL.

20D1

The pair task was rejected because Compatible FlashCopy SE is using the P-VOL or the P-VOL is a
TSE volume.

20D6

For more information about pair volume requirements, see

“Business Copy Z system requirements”

(page 11)

.

The pair task was rejected because the S-VOL is a TSE volume.

20D7

For more information about pair volume requirements, see

“Business Copy Z system requirements”

(page 11)

.

You cannot use the specified P-VOL for BC Z, because it is being used in BC.

20DC

The pair task was rejected because the volume you specified as the P-VOL is an external volume that
is mapped for online data migration.

20DE

The volume which was specified as the S-VOL cannot be used, because the volume is undergoing
online data migration.

20DF

The pair task was rejected because the volume you specified as the P-VOL is a Compatible FlashCopy
T-VOL.

22F6

The pair task was rejected because the volume you specified as the S-VOL is a Compatible FlashCopy
S-VOL or T-VOL.

22F7

The pair was not restored because the volume you specified as the S-VOL is a Compatible FlashCopy
S-VOL or T-VOL.

22F9

The pair task was rejected because there is not a sufficient amount of installed shared memory or BC
Z is not installed.

2301

The pair task was rejected because the LBA size of the specified P-VOL is not the same as the size of
the specified S-VOL.

2306

The pair was not created because the number of pairs exceeded the maximum number of pairs.

2309

The pair was not created because the volume you specified as the S-VOL is the P-VOL of the BC Z
pair that has an MU number of 0.

230A

The pair task was rejected because the pair is being suspended or deleted.

230B

One of the following occurred:

2310

Pair creation was rejected because the specified CG number had already been used for an L1
pair.

Pair creation was rejected because the specified CG number had already been used for an L2
pair.

Pair creation was rejected because the volume you specified as the P-VOL is the S-VOL of the pair
which is in the process of being Quick Split.

The Quick Restore was rejected because the VLL setting of the P-VOL is different from that of the
S-VOL.