Figure 20 3-data-center cascade configuration

Failure recovery occurs as follows:

If a failure occurs at the Cnt Ac-S Z P-VOL, business continues because data in the Cnt Ac-J Z
S-VOL is restored to the production system via the intermediate volume, if needed. Update
sequence integrity is ensured.

If a failure occurs at both Cnt Ac-S Z P-VOL and S-VOL, an implemented disaster recovery
plan would re-direct host activities to the Cnt Ac-J Z S-VOL.

See

“Recovery for 3 Cnt Ac-J Z/Cnt Ac-S Z or 3 Cnt Ac-J Z DC cascade configuration ” (page 107)

for recovery information and procedures.

Prerequisite information for 3DC cascade

P9500 must be installed at the local, Cnt Ac-S Z intermediate, and Cnt Ac-J Z remote sites.

Business Continuity Manager is recommended at all sites.

Remote Web Console is required at all sites.

Host application

Cnt Ac-S Z

Cnt Ac-S Z primary volume (P-VOL), the primary production volume

Cnt Ac-S Z fence level must be Data (CRIT=Y (ALL)).

The intermediate site requires the following:

Cnt Ac-S Z

Cnt Ac-J Z

Cnt Ac-S Z S-VOL = Cnt Ac-J Z P-VOL

Cnt Ac-J Z master journal volume

The remote site requires the following:

Cnt Ac-J Z

Cnt Ac-J Z S-VOL

Cnt Ac-J Z remote journal volume

Differential data is used to re-synchronize a suspended Cnt Ac-S Z or Cnt Ac-J Z pair.

When the Cnt Ac-S Z pair is recovered, the Cnt Ac-J Z pair in Duplex or Pending status is
automatically split by the system.

The fence level of the Cnt Ac-S Z P-VOL must be Data.

3DC cascade is not supported for multiple primary and secondary systems. The Cnt Ac-J Z or
Cnt Ac-S Z pair in this configuration would be suspended when the status became PAIR or
COPY.