Monitoring logical path status, History of pair operations – HP XP P9500 Storage User Manual

Page 91

Advertising
background image

Description

Status

A Cnt Ac-J delta resync pair is being created.

Holding

An error occurred with the Cnt Ac-J Z pair during the delta resync operation.

Hold(Failure)

This is an unused journal.

Blank

Monitoring logical path status

To view logical path status
1.

In the Remote Web Console main window, select Actions > Remote Copy > Continuous Access
Journal Z > DKC Operation.

2.

In the Display box, select DKC and select LDKC.

3.

Locate the remote system in the list on the right side and view the Status column.

4.

To see in-depth path status, right-click the remote system and select DKC Status.

Description

Item

Number of the row.

No

Status of a logical path. For status definitions and troubleshooting, see

“Troubleshooting logical

paths ” (page 114)

Path Status

Port on the local system.

Port

Port on the remote system.

Pair-Port

Serial number and LDKC number of the remote system.

S/N

Controller ID and model name (in parenthesis) for the remote system.

Controller ID

Path group ID

Path Gr. ID

Type of channel interface between local and remote systems. “Fibre” always dispays.

M-R Path

Minimum possible number of paths between the local and the remote systems.

Minimum Paths

Remote I/O missing interrupt handler timer value—the wait time for data transfer from the local
to remote system to complete.

RIO MIH

Date and time when local and remote systems were associated to each other

DKC Registered

Date and time the last operation on a logical path to the remote system was performed.

Last Updated

When clicked, the DKC Operation window refreshes when it re-displays.

Refresh the DKC
Operation tab after
this panel is closed

History of pair operations

The History window provides the history of pair operations. For example, the window shows the
date and time when data volume pairs are created or released.

To open the History window, do either of the following:

If Continuous Access Journal Z has not been started:

1.

In the Remote Web Console main window, select Actions > Remote Copy > Continuous Access
Journal Z > History.

The History window opens. The History window may not show the latest operation history.
To view the latest operation history, go to the next step.

2.

Select File > Refresh. The operation history is updated.

Monitoring logical path status