Page 60

Advertising
background image

2.

Click

to change the mode from View to Modify.

3.

In the Display box, select Port.

4.

In the list of ports, right-click the port that you want to change and select the desired port type:
Initiator, RCU Target, or Target).

5.

When you are finished defining ports, review the Preview list.

To change a setting, right-click the port in and select the attribute.

To delete a setting, right-click the port and select Delete.

6.

Click Apply to save your modifications in the system.

Configuring local and remote systems for Cnt Ac-J Z

You associate the primary and secondary systems in the Continuous Access Journal Z relationship
and define the logical paths between them in one procedure.

Prerequisite information

This procedure must be performed on both primary and secondary systems

The primary and secondary systems must already be configured for Continuous Access Journal
Z operations. See

“System requirements” (page 16)

for more information.

The data path must be set up. See

“Planning the data path” (page 41)

for more information.

The port attributes on the primary and secondary systems must be configured for Cnt Ac-J Z.
See

“Defining fibre-channel port attributes ” (page 59)

.

The system's serial number, LDKC number, controller ID, Path Gr. ID, and port number will be
required during this procedure.

Logical path settings are required in order to perform Continuous Access Journal Z pair
operations and check pair status in Remote Web Console. Make sure to complete the

60

Configuration operations