Table 38 Error Code and Error Contents When Operating RAID Manager (continued)

Error Content

Error Code

(SSB2)

Error Code

(SSB1)

The command was rejected because the command for XP Continuous Access
Synchronous was issued to the XP Continuous Access Asynchronous volume.

C23D

Pair cannot be created because the command was issued to the command device.

C267

The command was rejected because the specified consistency group number is
invalid.

C271

The command was rejected because the takeover command was issued to the volume
which status is not SSWS.

C28B

The command was rejected because RCU is not registered or the registered RCU
information is invalid.

C28C

There is no volume to which the takeover command can be executed.

C28D

The command was rejected because an internal logical error has occurred.

C28E

The command was rejected because the specified volume is used for S-VOL.

C297

Pair cannot be created because the capacity that is used by other than XP Continuous
Access Synchronous and XP Continuous Access Asynchronous exceeds the license
capacity.

C2A0

The command was rejected because an internal logical error has occurred.

C2A1

Pair cannot be created because the used capacity of XP Continuous Access
Synchronous exceeds the license capacity.

C2A3

Pair cannot be created because the used capacity of XP Continuous Access
Asynchronous exceeds the license capacity.

C2A4

The command was rejected because the changing of TP-VOL capacity is in progress.

C2B3

The command was rejected because an internal logical error has occurred.

C2B4

Pair cannot be created because the XP Continous Access P-VOL is being initialized
by XP Business Copy.

C2B5

The command was rejected because the releasing pages in TP-VOL is in progress.

C2B6

A request for Paircreate was received. However, the command was rejected because
the capacity that is used by XP Continuous Access in RCU exceeds the license
capacity. Check the license capacity, including the related program products.

C305

A request for Paircreate was received. However, the command was rejected because
the capacity that is used by XP Continuous Access in RCU exceeds the license
capacity. Check the license capacity, as well as the related program products.

C306

The volume in the RCU or another volume that belongs to the same group is changing
to the Simplex or Suspend status. Retry the operation several minutes later.

C30D

The P-VOL is not in the Simplex status.

C312

The P-VOL is not in the Suspend status.

C313

The P-VOL is not in the Simplex status.

C314

The P-VOL includes PIN data.

C315

The P-VOL is in the process of drive copy for failure assistance.

C316

The P-VOL is in the process of drive copy for an SVP request.

C317

The P-VOL is terminating the copy task.

C318

The PVOL is in the process of collection copy.

C319

164 Troubleshooting