Table 38 Error Code and Error Contents When Operating RAID Manager (continued)

Error Content

Error Code

(SSB2)

Error Code

(SSB1)

The P-VOL is in the process of collection access.

C31A

The P-VOL is blocked.

C31B

The P-VOL is blocked and impossible to access.

C31C

The P-VOL is in the process of format.

C31D

The P-VOL is for read only.

C31E

The number of MCU-RCU logical paths is 0 (for example, not specified).

C320

The number of MCU-RCU logical paths is smaller than the number of minimum paths
that are required to be specified.

C321

The DKC type of the MCU does not support XP Continuous Access.

C322

The RCU’s sequence number, SSID, or CU are invalid.

C324

Copy pair cannot be created because the P-VOL is not available for XP Continuous
Access Software.

C327

The track formats of the P-VOL and the S-VOL do not match.

C328

The S-VOL is protected by Data Retention Utility.

C32A

The P-VOL is protected by Data Retention Utility.

C32B

The S-VOL is protected by Data Retention Utility.

C32C

A request for Paircreate was received. However, the command was rejected because
the specified RCU is an unsupported product.

C32E

The number of cylinders of the XP Continuous Access P-VOLs is not same as or
smaller than that of S-VOLs.)

C32F

The XP Continuous Access volume capacity in the P-VOL is not equal to the one in
the S-VOL.

C330

The S-VOL cache is unavailable.

C332

The S-VOL DFW is disable.

C333

The S-VOL is the P-VOL for XP Continuous Access Asychronous.

C335

The S-VOL includes PIN data.

C336

The S-VOL is in the reserve status.

C337

Copy pair cannot be created because of one of the following reasons:

The S-VOL is in the intervention-required condition, protected, or unusable status.

The S-VOL is the S-VOL or Reserved volume of XP Business Copy, Reserved volume
of XP Auto LUN, or the volume of XP Continuous Access Journal pair.

C338

A request for Paircreate was received. However, the command was rejected because
the specified RCU is a product not supported by XP Continuous Access.

C33A

The corresponding volume cannot be specified as S-VOL because the volume is used
as another pair’s S-VOL.

C33B

A request for Paircreate was received. However, the command was rejected because
the specified S-VOL was not mounted.

C33C

Pair cannot be created because the S-VOL is not implemented or is blocked (DEV
NOT READY status).

C33E