HP StorageWorks XP Remote Web Console Software User Manual

Page 168

Advertising
background image

Table 38 Error Code and Error Contents When Operating RAID Manager (continued)

Error Content

Error Code

(SSB2)

Error Code

(SSB1)

In Pairresync, all difference setting was abnormally terminated.

CB21

(When connected to XP1024/XP128 Disk Array series) the port number and the
LUN exceed the range that can be set by the series.

CB5C

(When connected to XP1024/XP128 Disk Array series) the LUN and the device
number exceed the range that can be set by the series.

CB5D

When connected to the old model, LUSE pairs with different amounts of capacity
cannot be created.

CB5E

If the path is set between CUs, LUSE pairs with different CUs cannot be created.

CB5F

XP Continuous Access is not installed in the RCU.

CB60

One DKC cannot include both the pair using Escon and the pair using Fibre.

CB62

Paircreate cannot be executed because the P-VOL is the volume for an external
storage system.

CB6E

Paircreate cannot be executed because the S-VOL is the volume for an external
storage system

CB6F

Paircreate cannot be executed because the P-VOL is the migration volume for an
external storage system.

CB71

Paircreate cannot be executed because the S-VOL is the migration volume for an
external storage system.

CB73

The device is not recognized correctly.

CB75

Paircreate cannot be executed because the paths are specified per storage system.

CB76

The used capacity for Data Retention Utility program product on the RCU exceeds
the licence capacity.

CB77

Paircreate cannot be executed because the specified S-VOL is defined as the
command device.

CB78

A request for Paircreate was received. However, the command was rejected because
the specified S-VOL belongs to the different CLPR from the CLPR for the consistency
group that is already registered.

CB7E

Paircreate cannot be executed because the LUN for P-VOL is the LUSE which is
created across the multiple CLPRs.

CBD0

Paircreate cannot be executed because the LUN for S-VOL is the LUSE which is
created across the multiple CLPRs.

CBD1

A copy pair cannot be created because the specified P-VOL is not the P-VOL for XP
Continuous Access Journal.

CBD8

Paircreate cannot be executed because the used capacity for Data Retention Utility
program product on the RCU exceeds the licence capacity.

CBDA

A request for XP Continuous Access Paircreate was received in the XP Continuous
Access-XP Continuous Access Journal combination status. However, the command
was rejected because the Mirror ID for XP Continuous Access Journal was 0.

CBDC

In configuring the XP Continuous Access-XP Continuous Access Journal multi-target,
a request for an XP Continuous Access Paircreate was received. However, the
command was rejected because the XP Continuous Access Journal pair was in
process of copying.

CBDD

Paircreate cannot be executed because the P-VOL is used by XP Snapshot.

CBDE

Paircreate cannot be executed because the S-VOL is used by XP Snapshot.

CBDF

168 Troubleshooting

Advertising
This manual is related to the following products: