Rcu path parameters – HP StorageWorks XP Remote Web Console Software User Manual

Page 91

Advertising
background image

8.

Verify the requested operation(s) displayed in the preview list. To change one or more
operations, select the operation(s), right-click the preview list, and click Modify. To remove
one or more operations, select the operation(s), right-click the preview list, and click Delete.
To cancel all operations, select all the operations in the preview list, right-click, and click the
Delete command, or click the Cancel button.

9.

To start the operation(s), click the Apply button. The changes that you set are reflected in the
upper list on the window. The preview list is cleared. If one or more operation(s) did not start
normally, the preview list displays only the operation(s) that did not start normally. An error
code is displayed in the Error Code column in the preview list. To display the error message,
right-click the preview list, and click Error Detail. If errors occur simultaneously, the error
messages are displayed at the same time. Click the Apply button again.

RCU Path Parameters

For a Fibre Channel interface, two types of PCB mode settings are provided: Standard and High.
Therefore, when you configure paths among the initiator ports, target ports, and RCU target ports,
study the port modes and specify the correct mode for each port. For details on the relationship
between ports and PCB modes and instructions for setting the PCB mode, see the HP StorageWorks
XP24000/XP20000 LUN Manager User's Guide
.

Figure 33 (page 92)

shows a sample XP

Continuous Access Fibre Channel interface configuration with connections going through switches
and the XP Continuous Access Add RCU (Fibre) dialog box used to define this configuration.

RCU Operations

91