Automatic Failbacks

When a path recovers from an error, HDLM can automatically place the

recovered path back online. This function is called the automatic failback

function.

In order to use the automatic failback function, HDLM must already be

monitoring error recovery on a regular basis.

When using the Thunder 9500V series, or Hitachi AMS/WMS series, HDLM will

select the next path to be used first from among the online owner paths, and

then from the online non-owner paths. As a result, if an owner path recovers

from an error, and then HDLM automatically places the recovered path online

while a non-owner path is in use, the path will be automatically switched over

from the non-owner path to the owner path that just recovered from the

error.

When the Lightning 9900V series, Hitachi USP series, Universal Storage

Platform V/VM series, Virtual Storage Platform series, VSP G1000 series,
Hitachi AMS2000 series

#1

, Hitachi SMS series

#1

, HUS100 series

#1

or HUS

VM is being used, all the paths are owner paths. As a result, if the path that

was previously used recovers from an error, and then HDLM automatically

places the recovered path online, the path that is currently being used will

continue to be used (as opposed to switching over to the path that was just

recovered).

When intermittent errors

#2

occur on paths and you are using the automatic

failback function, the path status might frequently alternate between the

online and offline statuses. In such a case, because the performance of I/Os

will most likely decrease, if there are particular paths in which intermittent

errors might be occurring, we recommend that you set up intermittent error

monitoring so you can detect these paths, and then remove them from those

subject to automatic failbacks.

You can specify the automatic failback or intermittent error monitoring

function from the Options window of the HDLM GUI or by using the dlnkmgr

command's set operation. For details on operations from the Options

window, see the HDLM GUI Help. For details on the set operation, see

set

(Sets Up the Operating Environment) on page 6-16

.

#1

This storage system applies when the dynamic I/O path control function is

disabled.

#2

An intermittent error means an error that occurs irregularly because of

some reason such as a loose cable connection.

Manual Path Switching

You can switch the status of a path by manually placing the path online or

offline. Manually switching a path is useful, for example, when system

maintenance needs to be done.