Chapter 3 Preparing for Universal Replicator z/OS Operations

Hitachi Universal Replicator for IBM /OS User’s Guide

6. Create a URz pair that consists of a volume in the primary site and a

volume in the URz secondary site. Ensure that the primary data volume of

the resulting pair is the volume in the primary site, and that the secondary
data volume of the resulting pair is the volume in the URz secondary site.
To create this pair, use Business Continuity Manager to execute the

YKMAKE command on the journal group corresponding to that pair.
When the pair is created, the system configuration returns to the original

3DC multi-target configuration.
Note: YKMAKE is a command for establishing a pair.

Master

JNLVOL

Restore

JNLVOL

URz

Sec. data VOL

R-VOL

JNLVOL

R-VOL

JNLVOL

Restore

JNLVOL

URz

Sec. data VOL

Master

JNLVOL

業務

Tasks

業務

Tasks

Primary site

Primary site

TCz
Synchronous

TCz
Synchronous

TCz Synchronous

secondary site

TCz Synchronous

secondary site

M-VOL: main volume
R-VOL: remote volume
Prm data VOL: primary data volume
Sec. data VOL: secondary data volume
JNLVOL: journal volume

URz

secondary site

URz

secondary site

M-VOL/Prm.

data VOL

M-VOL/Prm.

data VOL

Figure 3-27

Transferring Business Tasks from TCz Secondary Site to the
Primary Site (in 3DC Multi-target Configuration)

Transferring Business Tasks from TCz Secondary Site to the Primary Site

(When Delta Resync Operation is Performed in 3DC multi-target

configuration)

If you remove failures from the primary site and other locations and then the
system is changed to 3DC multi-target configuration, you can transfer your

business tasks back to the primary site.

To transfer your business tasks back to the primary site, follow the procedure
below. Business Continuity Manager is used in this procedure:
1. If the TCz Synchronous pair is suspended, use Business Continuity Manager

to execute the YKRESYNC REVERSE command on the current TCz

Synchronous pair.