HP StorageWorks XP Remote Web Console Software User Manual

Page 158

Advertising
background image

4-24

Chapter 4 Using the Universal Replicator for z/OS GUI

Hitachi Universal Replicator for IBM /OS User’s Guide

Status Change by MCU(Suspend to Simplex): The status of the

data volume pair was changed from Suspend to Simplex because of an

operation from the primary storage system.
Status Change by MCU(Suspend to Pending): The status of the

data volume pair was changed from Suspend to Pending because of an
operation from the primary storage system.
Status Change by RCU(Suspend Pair Start): The status of the data

volume pair was changed because an operation for splitting a pair
started at the secondary storage system.
Status Change by RCU(Suspend Pair Complete): The status of the

data volume pair was changed because an operation for splitting a pair
finished at the secondary storage system.
Status Change by RCU(Suspend to Simplex; Delete Pair Start):

An operation for releasing a pair has been started at the secondary
storage system. The status of the data volume pair will change from
Suspend to Simplex.
Status Change by RCU(Pending to Simplex; Delete Pair Start): An

operation for releasing a pair has been started at the secondary storage
system. The status of the data volume pair will change from Pending to
Simplex.
Status Change by RCU(Duplex to Simplex; Delete Pair Start): An

operation for releasing a pair has been started at the secondary storage
system. The status of the data volume pair will change from Duplex to
Simplex.
Status Change by RCU(Delete Pair Complete): The status of the

data volume pair was changed because an operation for releasing a pair
finished at the secondary storage system.
Ready for Delta resync: A data volume pair became ready for delta

resync.
Ready for Delta resync(Failure):
The failure occurred with the data

volume pair which was ready for delta resync.
Status Change for Delta resync:
The status of the primary data

volume was changed to Hold because of a delta resync operation.
Status Change by MCU(Simplex to Hold):
The status of the data

volume pair was changed from Simplex to Hold because of an operation
from the primary storage system.
Status Change by MCU(Hold to Duplex):
The status of the data

volume pair was changed from Hold to Duplex because of an operation
from the primary storage system.
Status Change by MCU(Hold to Pending):
The status of the data

volume pair was changed from Hold to Pending because of an operation

from the primary storage system.